光子计数探测器CT血管造影用于血管内主动脉修复术后内漏检测:三相CT真实平扫与双相CT虚拟无碘成像的对比
回顾性纳入110例腹主动脉瘤血管内修复术后患者,比较光子计数探测器CT三相方案(真实平扫-动脉期-静脉期)与双相方案(虚拟无碘-动脉期-静脉期)的内漏检出效能与图像质量。两种方案内漏检出敏感度与特异度相当,阅片者间一致性均为显著,虚拟无碘图像客观噪声低于真实平扫,提示双相CT虚拟无碘成像可减少扫描期相与辐射暴露。
要点
- 双相CT虚拟无碘方案与三相CT真实平扫方案的内漏检出敏感度、特异度相当。
- 虚拟无碘图像主观噪声与真实平扫相当,客观噪声更低(11.5 HU vs 12.7 HU)。
- 双相虚拟无碘方案可减少扫描期相,提供降低辐射暴露的可能性。
核心结论
- 在光子计数探测器CT上,双相CT虚拟无碘成像与三相CT真实平扫成像的内漏检出效能和图像质量相当,提供减少扫描期相和辐射暴露的可能性。
研究设计与样本
- 回顾性纳入2021年8月至2022年7月间在光子计数探测器CT上接受三相检查(真实平扫、动脉期、静脉期)的腹主动脉瘤血管内修复术后成人患者,共110例(7例女性;年龄76±8岁),含41处内漏;虚拟无碘图像由静脉期重建;以放射学报告并经专家阅片者额外确认作为内漏存在的参考标准;由2名盲法放射科医师在两组阅片集上评估内漏检出;计算敏感度、特异度和阅片者间一致性(Krippendorf α);主观图像噪声采用5分制评估,体模中计算噪声功率谱。
诊断标准与关键数值
- 内漏检出敏感度/特异度:阅片者1真实平扫0.95/0.84 vs 虚拟无碘0.95/0.86;阅片者2真实平扫0.88/0.98 vs 虚拟无碘0.88/0.94;阅片者间一致性真实平扫0.716、虚拟无碘0.756,均为显著;主观图像噪声真实平扫4(IQR [4, 5])vs 虚拟无碘4(IQR [4, 5]),P=0.44;体模噪声功率谱峰值空间频率两者均为f peak=0.16 mm⁻¹;客观图像噪声真实平扫12.7 HU vs 虚拟无碘11.5 HU。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to compare image quality and endoleak detection after endovascular abdominal aortic aneurysm repair between a triphasic computed tomography (CT) with true noncontrast (TNC) and a biphasic CT with virtual noniodine (VNI) images on photon-counting detector CT (PCD-CT).
MATERIALS AND METHODS: Adult patients after endovascular abdominal aortic aneurysm repair who received a triphasic examination (TNC, arterial, venous phase) on a PCD-CT between August 2021 and July 2022 were retrospectively included. Endoleak detection was evaluated by 2 blinded radiologists on 2 different readout sets (triphasic CT with TNC-arterial-venous vs biphasic CT with VNI-arterial-venous). Virtual noniodine images were reconstructed from the venous phase. The radiologic report with additional confirmation by an expert reader served as reference standard for endoleak presence. Sensitivity, specificity, and interreader agreement (Krippendorf α) were calculated. Image noise was assessed subjectively in patients using a 5-point scale and objectively calculating the noise power spectrum in a phantom.
RESULTS: One hundred ten patients (7 women; age, 76 ± 8 years) with 41 endoleaks were included. Endoleak detection was comparable between both readout sets with a sensitivity and specificity of 0.95/0.84 (TNC) versus 0.95/0.86 (VNI) for reader 1 and 0.88/0.98 (TNC) versus 0.88/0.94 (VNI) for reader 2. Interreader agreement for endoleak detection was substantial (TNC: 0.716, VNI: 0.756). Subjective image noise was comparable between TNC and VNI (4; IQR [4, 5] vs 4; IQR [4, 5], P = 0.44). In the phantom, noise power spectrum peak spatial frequency was similar between TNC and VNI (both f peak = 0.16 mm -1 ). Objective image noise was higher in TNC (12.7 HU) as compared with VNI (11.5 HU).
CONCLUSIONS: Endoleak detection and image quality were comparable using VNI images in biphasic CT as compared with TNC images in triphasic CT offering the possibility to reduce scan phases and radiation exposure.