基于影像组学的T2加权前列腺MR图像自动化质量评估
研究纳入140例匿名轴位T2W前列腺MR图像,由两名读者共识用五分Likert量表评分并二分为临床可接受与不可接受,提取影像组学与Brisque特征构建LDA模型,独立测试集准确率85.4±5.5%,ROC-AUC为0.856(95%CI 0.851-0.861),提示影像组学AI可自动检出相当部分质量欠佳的T2W图像。
要点
- T2W前列腺MR图像质量变异大,影像组学模型可自动识别临床不可接受图像。
- 独立测试集分类准确率85.4±5.5%,ROC-AUC 0.856(95%CI 0.851-0.861)。
- 自动质量评估有助于在采集时改善图像质量,减少重复扫描。
核心结论
- 影像组学AI可自动检出相当部分质量欠佳的T2W图像,有助于在采集时改善图像质量,从而减少重复扫描并提高诊断准确率。
研究设计与样本
- 研究论文;140例患者的匿名轴位T2W图像,由两名读者共识用五分Likert量表评分并二分为临床可接受与不可接受,提取影像组学与Brisque特征,用线性判别分析(LDA)建模,采用200次重复5折交叉验证训练并评估性能。
诊断标准与关键数值
- 五分Likert量表:低、次优、可接受、好、很好;临床可接受包括很好、好、可接受,临床不可接受包括低和次优;34例为临床不可接受,106例为临床可接受;独立测试集准确率85.4±5.5%,ROC-AUC 0.856(95%CI 0.851-0.861)。
临床应用与阅片要点
- 作者认为影像组学AI可自动检出相当部分质量欠佳的T2W图像,有助于在采集时改善图像质量。
- 作者认为该技术可减少重复扫描并提高诊断准确率。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The guidelines for prostate cancer recommend the use of MRI in the prostate cancer pathway. Due to the variability in prostate MR image quality, the reliability of this technique in the detection of prostate cancer is highly variable in clinical practice. This leads to the need for an objective and automated assessment of image quality to ensure an adequate acquisition and hereby to improve the reliability of MRI. The aim of this study is to investigate the feasibility of Blind/referenceless image spatial quality evaluator (Brisque) and radiomics in automated image quality assessment of T2-weighted (T2W) images.
METHOD: Anonymized axial T2W images from 140 patients were scored for quality using a five-point Likert scale (low, suboptimal, acceptable, good, very good quality) in consensus by two readers. Images were dichotomized into clinically acceptable (very good, good and acceptable quality images) and clinically unacceptable (low and suboptimal quality images) in order to train and verify the model. Radiomics and Brisque features were extracted from a central cuboid volume including the prostate. A reduced feature set was used to fit a Linear Discriminant Analysis (LDA) model to predict image quality. Two hundred times repeated 5-fold cross-validation was used to train the model and test performance by assessing the classification accuracy, the discrimination accuracy as receiver operating curve - area under curve (ROC-AUC), and by generating confusion matrices.
RESULTS: Thirty-four images were classified as clinically unacceptable and 106 were classified as clinically acceptable. The accuracy of the independent test set (mean ± standard deviation) was 85.4 ± 5.5%. The ROC-AUC was 0.856 (0.851 - 0.861) (mean; 95% confidence interval).
CONCLUSIONS: Radiomics AI can automatically detect a significant portion of T2W images of suboptimal image quality. This can help improve image quality at the time of acquisition, thus reducing repeat scans and improving diagnostic accuracy.
引用
- Thijssen, de Rooij, Barentsz, et al. Radiomics based automated quality assessment for T2W prostate MR images. Eur J Radiol. 2023. PMID: 37354769. doi:10.1016/j.ejrad.2023.110928
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。