文献速递乳腺MR

利用高b值非高斯连续时间随机游走模型进行乳腺癌诊断与预后评估

Breast cancer diagnosis and prognosis using a high b-value non-Gaussian continuous-time random-walk model.
PubMed 文献 · Clin Radiol · 2023-06-08

回顾性分析85例乳腺病变(51恶性、34良性),比较单指数模型ADC与CTRW模型Dm、α、β及其组合鉴别良恶性的效能,并探讨参数与ER、PR、HER2、Ki-67的关联。Dm与ADC鉴别效能相似(AUC 0.928 vs 0.930),Dm、α、β组合AUC提高至0.969;ADC、Dm、α、β联合参数可区分ER+/ER-和PR+/PR-患者,α与PR表达显著相关。

要点

  • Dm与ADC鉴别乳腺良恶性效能相似,AUC分别为0.928与0.930。
  • Dm、α、β三参数组合可将AUC提升至0.969。
  • ADC、Dm、α、β联合参数可区分ER+/ER-和PR+/PR-患者。

核心结论

  • CTRW模型衍生的扩散参数可有效鉴别乳腺病变的良恶性;联合扩散参数可区分激素受体表达,并可能反映预后。

研究设计与样本

  • 回顾性研究,纳入85例乳腺病变患者(51例恶性、34例良性),采用单指数模型(b值=0、800 s/mm²)拟合ADC,CTRW模型拟合Dm、α、β,参考标准为免疫组化指标ER、PR、HER2、Ki-67。

诊断标准与关键数值

  • Dm鉴别乳腺良恶性的AUC=0.928,ADC的AUC=0.930。
  • Dm、α、β三参数组合的AUC=0.969。
  • ADC、Dm、α、β联合参数可识别ER+/ER-和PR+/PR-患者。
  • 时间异质性参数α与PR表达显著相关(p<0.05)。

临床应用与阅片要点

  • CTRW模型参数Dm、α、β及其组合可用于乳腺病变良恶性鉴别,Dm、α、β组合的AUC高于单独Dm或ADC。
  • 联合ADC、Dm、α、β参数可能用于区分激素受体表达状态,α与PR表达相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To compare the diagnostic performance of mono-exponential model-derived apparent diffusion coefficient (ADC), continuous-time random-walk (CTRW) model-derived Dm, α, β and their combinations in discriminating malignancy of breast lesions, and investigate the association between model-derived parameters and prognosis-related immunohistochemical indices.

MATERIALS AND METHODS: A total of 85 patients with breast lesions (51 malignant, 34 benign) were analysed in this retrospective study. Clinical characteristics include oestrogen receptor (ER), progesterone receptor (PR), human epidermal receptor 2 (HER2), and Ki-67. The ADC was fitted using a mono-exponential model (b-values = 0, 800 s/mm2), while Dm, α, and β were fitted using a CTRW model. Independent Student's t-test and the Mann-Whitney U-test were used for the comparison of parameters. Discrimination performance was accomplished by receiver operating characteristic (ROC) analysis, and Spearman's correlation analysis was used to explore the association between immunohistochemical indices and diffusion parameters, the statistical significance level was p<0.05.

RESULTS: Dm and ADC demonstrated similar performance in differentiating malignant and benign lesions (AUC = 0.928 versus 0.930), while the combination of Dm, α, and β could improve the AUC to 0.969. The combined parameter generated by ADC, Dm, α, and β was effective in identifying the ER+/ER- and PR+/PR- patients. Temporal heterogeneity parameter α correlated significantly with the expression of PR.

CONCLUSION: Diffusion parameters derived from the CTRW model could effectively discriminate the malignancy of breast lesions. Meanwhile, the hormone receptor expression could be distinguished by combined diffusion parameters, and have the potential to reflect the prognosis.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Feng, Liu, Wang, et al. Breast cancer diagnosis and prognosis using a high b-value non-Gaussian continuous-time random-walk model. Clin Radiol. 2023. PMID: 37344324. doi:10.1016/j.crad.2023.05.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。