心肌声学造影在检测非阻塞性冠状动脉疾病缺血患者冠状动脉微循环功能障碍中的价值
研究纳入21例临床诊断为非阻塞性冠状动脉疾病缺血的胸痛患者,均行心肌声学造影和[18F]氟脱氧葡萄糖正电子发射断层扫描/计算机断层扫描心肌代谢显像,以FDG PET为金标准将心肌节段分为冠状动脉微循环功能障碍组和正常对照组。结果显示功能障碍组β、A和A×β降低,基底段TTP延长,ROC曲线分析显示β在中段诊断效能最高。
要点
- 心肌声学造影参数β、A和A×β在冠状动脉微循环功能障碍组降低,基底段TTP延长。
- 以FDG PET为金标准,β在中段的诊断效能最高。
- 心肌声学造影对非阻塞性冠状动脉疾病合并冠状动脉微循环功能障碍有诊断价值。
核心结论
- 心肌声学造影对诊断非阻塞性冠状动脉疾病合并冠状动脉微循环功能障碍有价值。
研究设计与样本
- 研究纳入21例临床诊断为非阻塞性冠状动脉疾病缺血的胸痛患者,均行心肌声学造影和[18F]氟脱氧葡萄糖正电子发射断层扫描/计算机断层扫描心肌代谢显像,以FDG PET结果为金标准将心肌节段分为冠状动脉微循环功能障碍组和正常对照组。
关键影像表现/征象
- 冠状动脉微循环功能障碍组所有节段的心肌灌注参数β、A和A×β降低,基底段TTP较正常对照组延长(所有p值<0.05)。
诊断标准与关键数值
- 冠状动脉微循环功能障碍组共122个节段,正常对照组共218个节段。
- ROC曲线分析显示β在中段的诊断效能最高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The aim of this study was to evaluate the value of myocardial contrast echocardiography (MCE) in detecting coronary microcirculation function dysfunction in ischemia with non-obstructive coronary artery (INOCA) disease.
METHODS: Twenty-one patients with a clinical diagnosis of INOCA were admitted to the First Affiliated Hospital of Xinjiang Medical University because of chest pain. All participants underwent MCE and [18F]fluorodeoxyglucose (FDG) positron emission tomography/computed tomography myocardial metabolic imaging. With the results of FDG PET taken as the gold standard, all myocardial segments were divided into a normal control group and a coronary artery microcirculation dysfunction (CMCD) group. We used MCE to measure myocardial perfusion parameters, including the ascending slope (β), time to peak (TTP), A and A × β. The receiver operating characteristic (ROC) curves of β, TTP, A and A × β were calculated to evaluate the diagnostic value of MCE for CMCD.
RESULTS: A total of 122 and 218 segments were investigated in the CMCD and control groups, respectively. On the basis of the statistical analysis of the MCE parameters of the two groups, the myocardial perfusion parameters β, A and A × β of all segments in the CMCD group decreased, and the TTP in the basal segment of the CMCD group was longer than that of the normal control group (all p values <0.05). On the basis of analysis of the ROC curve, β had the highest diagnostic efficiency in the middle segment.
CONCLUSION: This study found that MCE is valuable in the diagnosis of non-obstructive coronary artery complicated by CMCD.
引用
- Zhang, Guan, Li, et al. Value of Myocardial Contrast Echocardiography in Detecting Coronary Microcirculatory Dysfunction in Ischemia With Non-obstructive Coronary Artery Disease. Ultrasound Med Biol. 2023. PMID: 37344240. doi:10.1016/j.ultrasmedbio.2023.05.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。