基于CT的影像组学列线图鉴别卵巢囊腺瘤与子宫内膜异位囊肿
本研究纳入287例卵巢囊腺瘤(n=196)或子宫内膜异位囊肿(n=91)患者,随机分为训练队列(n=200)和验证队列(n=87),基于CT门静脉期图像提取影像组学特征构建列线图。列线图整合CA-125水平和影像组学评分,在训练队列和验证队列的AUC分别为0.925(95%CI:0.885-0.965)和0.942(95%CI:0.891-0.993),验证队列混淆矩阵准确率优于放射科医生。
要点
- 基于CT门静脉期影像组学列线图鉴别卵巢囊腺瘤与子宫内膜异位囊肿,验证队列AUC为0.942。
- 列线图整合CA-125水平与影像组学评分,诊断准确率优于放射科医生。
- 影像组学列线图可能有助于临床决策过程。
核心结论
- 基于CT的影像组学列线图在鉴别卵巢囊腺瘤与子宫内膜异位囊肿方面表现良好,可能有助于临床决策过程。
研究设计与样本
- 回顾性研究?原文未写明研究类型;共纳入287例患者(卵巢囊腺瘤n=196,子宫内膜异位囊肿n=91),随机分为训练队列(n=200)和验证队列(n=87);基于CT门静脉期图像提取影像组学特征,使用PyRadiomics提取,采用最小绝对收缩和选择算子回归筛选特征并构建影像组学标签;参考标准为临床诊断?原文未明确。
诊断标准与关键数值
- 影像组学列线图整合CA-125水平和影像组学评分,训练队列AUC为0.925(95%CI:0.885-0.965),验证队列AUC为0.942(95%CI:0.891-0.993);共选用17个CT影像组学特征构建影像组学标签。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To construct and validate a computed tomography (CT)-based radiomics nomogram integrating radiomics signature and clinical factors to distinguish ovarian cystadenomas and endometriotic cysts.
MATERIALS AND METHODS: A total of 287 patients with ovarian cystadenomas (n=196) or endometriotic cysts (n=91) were divided randomly into a training cohort (n=200) and a validation cohort (n=87). Radiomics features based on the portal venous phase of CT images were extracted by PyRadiomics. The least absolute shrinkage and selection operation regression was applied to select the significant features and develop the radiomics signature. A radiomics score (rad-score) was calculated. The clinical model was built by the significant clinical factors. Multivariate logistic regression analysis was employed to construct the radiomics nomogram based on significant clinical factors and rad-score. The diagnostic performances of the radiomics nomogram, radiomics signature, and clinical model were evaluated and compared in the training and validation cohorts. Diagnostic confusion matrices of these models were calculated for the validation cohort and compared with those of the radiologists.
RESULTS: Seventeen radiomics features from CT images were used to build the radiomics signature. The radiomics nomogram incorporating cancer antigen 125 (CA-125) level and rad-score showed the best performance in both the training and validation cohorts with AUCs of 0.925 (95% confidence interval [CI]: 0.885-0.965), and 0.942 (95% CI: 0.891-0.993), respectively. The accuracy of radiomics nomogram in the confusion matrix outperformed the radiologists.
CONCLUSIONS: The radiomics nomogram performed well for differentiating ovarian cystadenomas and endometriotic cysts, and may help in clinical decision-making process.
引用
- Li, Wang, Ma, et al. A CT-based radiomics nomogram for differentiating ovarian cystadenomas and endometriotic cysts. Clin Radiol. 2023. PMID: 37336676. doi:10.1016/j.crad.2023.05.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。