超声医师经腹与经阴道宫颈长度测量的一致性及相关患者人口学因素
前瞻性队列研究纳入530例孕18至22周6天单胎孕妇,在解剖超声时行经腹与经阴道宫颈长度测量,36%(95%CI 32-40%)经腹测量不准确;经腹宫颈长度>3.40 cm时平均低估经阴道值,<3.40 cm时平均高估;经腹超声检出经阴道宫颈长度<2.5 cm的敏感度仅25%、特异度98.5%;西班牙裔与经腹测量不准确相关(OR 0.48,95%CI 0.24-0.96,P=.04)。
要点
- 经腹宫颈长度测量36%不准确,与经阴道测量差值>0.5 cm即判为不准确。
- 经腹超声预测短宫颈(经阴道<2.5 cm)敏感度25%、特异度98.5%,敏感度低。
- 经腹宫颈长度<3.4 cm时平均高估经阴道值,>3.40 cm时平均低估。
核心结论
- 经腹宫颈长度测量平均在经阴道宫颈长度>3.40 cm时低估、<3.40 cm时高估;经腹超声预测短宫颈敏感度低,仅依赖经腹宫颈长度识别需干预者可能漏诊;作者认为对经腹宫颈长度<3.4 cm者采用经阴道宫颈长度测量的方案可能是合理的。
研究设计与样本
- 前瞻性队列研究,纳入530例孕18至22周6天单胎孕妇,排除<18岁及双胎妊娠;解剖超声时行经腹与经阴道宫颈长度测量、评估胎盘边缘至宫颈内口距离并完成人口学问卷。
诊断标准与关键数值
- 经腹宫颈长度与经阴道长度相差>0.5 cm判为不准确;经腹与经阴道宫颈长度平均差值恰为0对应的宫颈长度为3.4 cm;经腹超声检出经阴道宫颈长度<2.5 cm的敏感度25%、特异度98.5%。
临床应用与阅片要点
- 作者认为对经腹宫颈长度<3.4 cm者采用经阴道宫颈长度测量的方案可能是合理的;仅依赖经腹宫颈长度识别需干预者可能漏诊。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess transvaginal (TV) and transabdominal (TA) cervical length (CL) measurements' variability and patient factors associated with TA CL accuracy. We hypothesized that patient factors would affect the accuracy of TA CL.
METHODS: This was a prospective cohort study. During anatomy ultrasound, TA and TV CL measurements were obtained, distance from placental edge to internal cervical os assessed, and demographic questionnaires completed. Patients between 18 to 22 weeks and 6 days were included and those <18 year old or with a twin gestation were excluded. TA CL >0.5 cm different from TV length was considered inaccurate.
RESULTS: A total of 530 patients were included. Exactly 18.7% had a prior cesarean, 9.8% a preterm birth, and 2.2% a cervical procedure. Mean age and BMI were 31.1 years and 27.8 kg/m2 . Median number of living children was one. Median TA and TV CL were 3.42 and 3.53 cm. Exactly 36% (95% CI: 32-40%) of TA CL measurements were inaccurate. CL of 3.4 cm corresponded to a mean difference of zero between TA and TV CL. TA ultrasound had a sensitivity of 25% and a specificity of 98.5% to detect TV CL <2.5 cm. On multivariable analyses, Hispanic ethnicity was associated with inaccurate TA measurement (OR 0.48, 95% CI: 0.24-0.96, P = .04).
CONCLUSIONS: On average, TA CL underestimates TV CL when TV CL >3.40 cm and overestimates TV CL when TV CL <3.40 cm. Additional co-variates did not impact accuracy. TA ultrasound has low sensitivity to predict short cervix. Relying solely on TA CL to identify those who need intervention may miss diagnoses. It may be reasonable to develop protocols in which TV CL is used for TA CL <3.4 cm.
引用
- Peterson, Smolar, Stoffels, et al. Intra-Sonographer Correlation Between Transabdominal and Transvaginal Cervical Length Measurements and Associated Patient Demographics. J Ultrasound Med. 2023. PMID: 37334907. doi:10.1002/jum.16293
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。