文献速递胸部心血管CT

评估人工智能评估工具在常规胸部CT上测量胸主动脉直径的作用

Assessing the role of an artificial intelligence assessment tool for thoracic aorta diameter on routine chest CT.
PubMed 文献 · Br J Radiol · 2023-07-26

单中心回顾性研究纳入三个队列,评估人工智能自动测量常规胸部CT胸主动脉直径的诊断准确性与临床影响。人工智能与专家测量在升主动脉中段一致性良好,但在非专用胸部CT上检测主动脉扩张特异性高(99%)而敏感度低(77%)。

要点

  • 人工智能与专家在升主动脉中段测量一致性良好(ICC 0.76-0.92)。
  • 在非专用胸部CT上,人工智能新发现27%患者主动脉扩张,特异度99%、敏感度77%。
  • 在心电门控CT上,人工智能在主动脉根部的诊断性能超过最大可接受限(>5 mm)。

核心结论

  • 人工智能在升主动脉中段与专家读者一致性良好,但在非专用胸部CT上检测主动脉扩张特异性高而敏感度低。
  • 人工智能工具有可能较当前常规报告改善胸部CT上既往未知胸主动脉扩张的检出。

研究设计与样本

  • 单中心回顾性研究,涉及三个队列。
  • 第一队列:210例连续心电门控CT主动脉扫描(平均年龄75±13岁),行自动分析(AI-Rad Companion Chest CT,Siemens),以专科心胸放射科医师为参考标准比较主动脉直径测量准确性。
  • 第二队列:29例患者(平均年龄61±17岁),行即刻连续平扫与增强CT主动脉采集,采用重复测量分析检验报告一致性。
  • 第三队列:197例常规胸部CT(平均年龄66±15岁),评估潜在临床影响。

诊断标准与关键数值

  • 人工智能分析在387/436(89%)中生成完整报告,在421/436(97%)中生成部分报告。
  • 手动与人工智能一致性良好至优秀(ICC 0.76-0.92)。
  • 专家与人工智能对升主动脉报告的重复测量分析一致性为中等至良好(ICC 0.57-0.88)。
  • 人工智能在心电门控CT上主动脉根部的诊断性能超过最大可接受限(>5 mm)。
  • 人工智能在常规胸部影像上新识别27%患者的主动脉扩张,特异度99%、敏感度77%。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the diagnostic accuracy and clinical impact of automated artificial intelligence (AI) measurement of thoracic aorta diameter on routine chest CT.

METHODS: A single-centre retrospective study involving three cohorts. 210 consecutive ECG-gated CT aorta scans (mean age 75 ± 13) underwent automated analysis (AI-Rad Companion Chest CT, Siemens) and were compared to a reference standard of specialist cardiothoracic radiologists for accuracy measuring aortic diameter. A repeated measures analysis tested reporting consistency in a second cohort (29 patients, mean age 61 ± 17) of immediate sequential pre-contrast and contrast CT aorta acquisitions. Potential clinical impact was assessed in a third cohort of 197 routine CT chests (mean age 66 ± 15) to document potential clinical impact.

RESULTS: AI analysis produced a full report in 387/436 (89%) and a partial report in 421/436 (97%). Manual vs AI agreement was good to excellent (ICC 0.76-0.92). Repeated measures analysis of expert and AI reports for the ascending aorta were moderate to good (ICC 0.57-0.88). AI diagnostic performance crossed the threshold for maximally accepted limits of agreement (>5 mm) at the aortic root on ECG-gated CTs. AI newly identified aortic dilatation in 27% of patients on routine thoracic imaging with a specificity of 99% and sensitivity of 77%.

CONCLUSION: AI has good agreement with expert readers at the mid-ascending aorta and has high specificity, but low sensitivity, at detecting dilated aortas on non-dedicated chest CTs.

ADVANCES IN KNOWLEDGE: An AI tool may improve the detection of previously unknown thoracic aorta dilatation on chest CTs vs current routine reporting.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Graby, Harris, Jones, et al. Assessing the role of an artificial intelligence assessment tool for thoracic aorta diameter on routine chest CT. Br J Radiol. 2023. PMID: 37335231. doi:10.1259/bjr.20220853

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。