对比增强超声与高敏感多普勒监测子宫动脉栓塞术疗效
本研究纳入40例子宫肌瘤患者,在子宫动脉栓塞术(UAE)后第0、15、90天使用彩色多普勒、能量多普勒、彩色与单色SMI及对比增强超声(CEUS)评估肌瘤血管性。CEUS与SMI可准确评估肌瘤微血管性,有望成为监测UAE疗效的无创方法。
要点
- CEUS与SMI评估肌瘤微血管性的组间一致性较好(κ=0.70,P=0.25)。
- CEUS测得的肌瘤血管分数(FV)与各多普勒模式在三个时间点均有统计学显著差异(P<0.0001)。
- 多普勒模式间血流强度在UAE后90天无统计学显著差异(P=0.34)。
核心结论
- CEUS和SMI能准确评估肌瘤微血管性,因此可能成为监测UAE术后疗效的无创且准确的方法。
研究设计与样本
- 经机构审查委员会批准的研究,纳入40例有症状的子宫肌瘤并计划行UAE的女性,在UAE后第0、15、90天进行彩色多普勒(CDI)、能量多普勒(PDI)、彩色与单色SMI(cSMI、mSMI)及CEUS检查,由两名放射科医师评估肌瘤血管性分类,并定量肌瘤血管分数(FV,强化像素占肌瘤的百分比)和血流强度(强化像素的平均亮度水平)。
诊断标准与关键数值
- CEUS与CDI、PDI、cSMI、mSMI在三个检查时间的FV比较均有统计学显著差异(P<0.0001)。
- CDI、PDI、cSMI三者的FV比较无统计学显著差异(P=0.53)。
- CDI、PDI、cSMI、mSMI各多普勒模式间的血流强度比较在UAE后90天以外的时点有统计学显著差异(P=0.02),UAE后90天无统计学显著差异(P=0.34)。
- CDI、PDI、cSMI三者的血流强度比较无统计学显著差异(P<0.47)。
- 两名阅片者对所有成像模式和检查时间的一致性总体较好(P=0.25;κ=0.70)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To monitor fibroid microvascularity using contrast-enhanced ultrasound (CEUS) and a new high-sensitive Doppler mode (SMI) for assessment of uterine artery embolization (UAE) outcomes.
MATERIALS AND METHODS: Forty women with symptomatic uterine fibroids scheduled for UAE were enrolled in this Institutional Review Board-approved study. Subjects underwent three examinations (day 0, 15, and 90 post-UAE) with Color Doppler (CDI), power Doppler (PDI), color and monochrome SMI (cSMI and mSMI), and CEUS imaging of the fibroids. Clips were assessed by two radiologists classifying fibroids based on their vascularity. Fibroid fractional vascularity (FV; % of enhanced pixels within the fibroid) and flow intensity (as mean brightness level of the enhanced pixels) were quantified. Results were analyzed using repeated measures ANOVA and nonparametric Wilcoxon sign rank tests. Inter-reader agreement was assessed with κ-values.
RESULTS: There was overall agreement between readers for all imaging modalities and examination times (P = .25; κ = 0.70). The FV analysis showed statistically significant differences between CEUS and the Doppler imaging modes (CDI, PDI, cSMI, and mSMI) for the three examination times were compared (P < .0001). The comparison using CDI, PDI, and cSMI showed no statistically significant difference (P = .53). The flow intensity analysis comparison between the Doppler imaging modes (CDI, PDI, cSMI and mSMI) and examination times showed statistically significant differences between all the Doppler imaging modalities (P = .02), except for the 90days post-UAE (P = .34). When the comparison was made for CDI, PDI, and cSMI there was no statistically significant differences (P < .47).
CONCLUSION: CEUS and SMI can accurately evaluate fibroid microvascularity, and therefore, can be a noninvasive and accurate method for monitoring outcomes following UAE treatment.
引用
- Machado, Gillmore, Tan, et al. Contrast-Enhanced Ultrasound and High Sensitive Doppler for Monitoring Outcomes of Uterine Artery Embolization. Acad Radiol. 2023. PMID: 37330354. doi:10.1016/j.acra.2023.04.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。