俯卧位PET/CT有助于减少重力依赖性密度影相关的[18F]氟脱氧葡萄糖摄取
回顾性分析135例同时行仰卧位和俯卧位[18F]FDG PET/CT的患者,比较依赖性与非依赖性肺的摄取和CT密度。仰卧位依赖性肺SUVmean和HU显著高于非依赖性肺,俯卧位时差异减小;SUVmean与HU在仰卧位呈强相关(R=0.86),俯卧位呈中度相关(R=0.65)。仰卧位85.2%患者后肺可见目视可辨的[18F]FDG摄取,俯卧位除1例外均消失。
要点
- 仰卧位PET/CT中依赖性肺SUVmean和HU显著高于非依赖性肺,俯卧位时差异减小。
- 仰卧位85.2%患者后肺可见目视可辨的[18F]FDG摄取,俯卧位除1例外均消失。
- SUVmean与HU在仰卧位呈强相关(R=0.86),俯卧位呈中度相关(R=0.65)。
核心结论
- 肺[18F]FDG摄取与HU呈中度至强相关,俯卧位PET/CT可有效减少重力依赖性密度影相关的[18F]FDG摄取。
研究设计与样本
- 回顾性研究,纳入2018年10月至2021年9月间同时行仰卧位和俯卧位[18F]FDG PET/CT的患者135例(中位年龄66岁,四分位距58-75岁;男性80例),对依赖性和非依赖性肺的[18F]FDG摄取进行视觉和半定量分析,采用线性回归分析SUVmean与HU的关联。
关键影像表现/征象
- 仰卧位PET/CT中依赖性肺SUVmean高于非依赖性肺(0.59±0.14 vs. 0.36±0.09,p<0.001),HU亦更高(-671±66 vs. -802±43,p<0.001)。
- 俯卧位PET/CT中依赖性肺SUVmean仍高于非依赖性肺(0.45±0.12 vs. 0.42±0.08,p<0.001),HU亦更高(-731±67 vs. -790±40,p<0.001)。
- 仰卧位PET/CT中115例(85.2%)患者后肺可见目视可辨的[18F]FDG摄取,俯卧位时除1例(0.7%)外均消失(p<0.001)。
诊断标准与关键数值
- 线性回归分析显示SUVmean与HU在仰卧位PET/CT中呈强相关(R=0.86,p<0.001),在俯卧位PET/CT中呈中度相关(R=0.65,p<0.001)。
临床应用与阅片要点
- 俯卧位PET/CT可减少重力依赖性密度影相关的[18F]FDG摄取,可能提高评估依赖性肺结节的诊断准确性。
- 俯卧位PET/CT可能为间质性肺病评估中的肺炎症参数提供更准确的评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study aimed to investigate whether performing [18F]fluorodeoxyglucose ([18F]FDG) positron emission tomography/computed tomography (PET/CT) in the prone position could reduce [18F]FDG uptake in dependent lungs.
METHODS: Patients who underwent [18F]FDG PET/CT in both supine and prone positions from October 2018 to September 2021 were reviewed retrospectively. [18F]FDG uptake of dependent and nondependent lungs was analysed visually and semi-quantitatively. A linear regression analysis was performed to examine the association between the mean standardised uptake value (SUVmean) and the Hounsfield unit (HU).
RESULTS: A total of 135 patients (median age, 66 years [interquartile range: 58-75 years]; 80 men) were included. Dependent lungs showed significantly higher SUVmean and HU than nondependent lungs on supine position PET/CT (sPET/CT, 0.59 ± 0.14 vs. 0.36 ± 0.09, p < 0.001; - 671 ± 66 vs. - 802 ± 43, p < 0.001, respectively) and prone position PET/CT (pPET/CT, 0.45 ± 0.12 vs. 0.42 ± 0.08, p < 0.001; - 731 ± 67 vs. - 790 ± 40, p < 0.001, respectively). Linear regression analysis revealed a strong association between the SUVmean and HU in sPET/CT (R = 0.86, p < 0.001) and moderate association in pPET/CT (R = 0.65, p < 0.001). One hundred and fifteen patients (85.2%) had visually discernible [18F]FDG uptake in the posterior lung on sPET/CT, which disappeared on pPET/CT in all but one patient (0.7%, p < 0.001).
CONCLUSIONS: [18F]FDG uptake of the lung had moderate-to-strong associations with HU. Gravity-dependent opacity-related [18F]FDG uptake can be effectively reduced on prone position PET/CT.
CLINICAL RELEVANCE STATEMENT: Prone position PET/CT effectively reduces gravity-dependent opacity-related [18F]fluorodeoxyglucose uptake in the lung, potentially improving diagnostic accuracy in evaluating nodules in dependent lungs and offering a more accurate assessment of lung inflammation parameters in interstitial lung disease evaluations.
KEY POINTS: • The study evaluated whether performing [18F]fluorodeoxyglucose ([18F]FDG) PET/CT could reduce [18F]FDG uptake in lungs. • In prone and supine position PET/CT, the [18F]FDG uptake and Hounsfield unit were moderately to strongly associated. • Prone position PET/CT can reduce gravity-dependent opacity-related [18F]FDG uptake by the posterior lung.
引用
- Song, Moon, Kim, et al. Prone position PET/CT is useful in reducing gravity-dependent opacity-related [18F]fluorodeoxyglucose uptake. Eur Radiol. 2023. PMID: 37322163. doi:10.1007/s00330-023-09831-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。