文献速递神经介入技术与安全透视

用于透视引导下侧方C1-C2脊柱穿刺培训的低成本颈椎体模的开发与应用

The Development and Application of a Cost-Effective Cervical Spine Phantom for Use in Fluoroscopically Guided Lateral C1-C2 Spinal Puncture Training.
PubMed 文献 · AJNR Am J Neuroradiol · 2023-06-15

本研究开发了一种低成本可重复使用的颈椎体模,用于透视引导下侧方C1-C2脊柱穿刺培训,21名学员参加培训后舒适度、信心和知识均显著提高,81%的参与者认为模型非常有帮助,所有参与者都非常可能推荐该工作坊。

要点

  • 该体模成本约70美元,由颈椎模型、代表硬膜囊的外管、代表脊髓的内气球和模拟软组织的聚藻酸盐构成。
  • 21名学员培训后舒适度提高2.00分(SD 1.00,P<.001),信心提高1.52分(SD 0.87,P<.001),知识提高2.19分(SD 0.93,P<.001)。
  • 81%的参与者认为模型非常有帮助(Likert 5/5),所有参与者都非常可能向他人推荐该工作坊。

核心结论

  • 该颈椎体模成本低、可复制,具有培训效用,可为住院医师进行侧方C1-C2脊柱穿刺做准备;由于该操作罕见,在接触患者前使用体模模型对住院医师教育和培训非常有价值。

研究设计与样本

  • 研究为体模开发与评估,使用颈椎模型、代表硬膜囊的外管、代表脊髓的内气球和聚藻酸盐构建体模,材料总成本约70美元;由经验丰富的神经放射学教师带领在透视下使用模型进行工作坊培训;参与者为21名学员,采用5点Likert量表进行前后问卷调查,评估舒适度、信心和操作步骤知识。

诊断标准与关键数值

  • 舒适度提高2.00分(SD 1.00,P<.001),信心提高1.52分(SD 0.87,P<.001),知识提高2.19分(SD 0.93,P<.001)。
  • 81%的参与者认为模型非常有帮助(Likert量表5/5分),所有参与者都非常可能向他人推荐该工作坊。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Lateral C1-C2 spinal punctures are uncommon procedures performed by radiologists for access to CSF and contrast injection when a lumbar approach is contraindicated and an alternate method of access becomes necessary. There are limited opportunities to learn and practice the technique. We aimed to develop and assess the efficacy of a low-cost, reusable cervical spine phantom for training in fluoroscopically guided lateral C1-C2 spinal puncture.

MATERIALS AND METHODS: The phantom was constructed with a cervical spine model, an outer tube representing the thecal sac, an inner balloon representing the spinal cord, and polyalginate to replicate soft tissue. The total cost of materials was approximately US $70. Workshops were led by neuroradiology faculty experienced in the procedure using the model under fluoroscopy. Survey questions were assessed on a 5-point Likert scale. Participants were given pre- and postsurveys assessing comfort, confidence, and knowledge of steps.

RESULTS: Twenty-one trainees underwent training sessions. There was significant improvement in comfort level (Δ: 2.00, SD: 1.00, P value < .001); confidence (Δ: 1.52 points, SD: 0.87, P value < .001); and knowledge (Δ: 2.19, SD: 0.93, P value < .001). Eighty-one percent of participants found the model "very helpful" (5/5 on Likert scale), and all participants were "very likely" to recommend this workshop to others.

CONCLUSIONS: This cervical phantom model is affordable and replicable and demonstrates training utility to prepare residents for performing lateral C1-C2 spinal puncture. This is a rare procedure, so the use of a phantom model before patient encounters is invaluable to resident education and training.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Risner, Huang, McCullagh, et al. The Development and Application of a Cost-Effective Cervical Spine Phantom for Use in Fluoroscopically Guided Lateral C1-C2 Spinal Puncture Training. AJNR Am J Neuroradiol. 2023. PMID: 37321858. doi:10.3174/ajnr.A7908

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。