前列腺影像质量(PI-QUAL)评分在基础阅片者中的阅片者间一致性:一项多中心研究
该多中心研究纳入355例男性前列腺mpMRI数据,由5名来自不同中心的基础前列腺阅片者依据PI-QUAL评分独立评估图像质量,结果显示PI-QUAL评分的配对加权Cohen kappa为0.656至0.786,提示阅片者间一致性良好。
要点
- PI-QUAL评分在基础阅片者间配对kappa为0.656–0.786,一致性良好。
- T2WI、ADC图、DCE序列诊断充分性的配对绝对一致率分别为0.75–0.88、0.74–0.83、0.77–0.86。
- 基础阅片者使用PI-QUAL评分在多中心数据上可重复性良好。
核心结论
- 来自不同机构的基础前列腺放射科医生在多中心数据上对PI-QUAL评分给出了良好的阅片者间一致性。
研究设计与样本
- 多中心研究,纳入355例男性(中位年龄71岁,IQR 60–78),5名来自不同中心的基础前列腺阅片者独立评估PI-QUAL评分,使用T2WI、DWI(含ADC图)和DCE图像,参照PI-RADS v2.1。
诊断标准与关键数值
- PI-QUAL评分的配对加权Cohen kappa范围为0.656至0.786,提示阅片者间一致性良好。
- T2WI诊断充分性的配对绝对一致率范围为0.75至0.88。
- ADC图诊断充分性的配对绝对一致率范围为0.74至0.83。
- DCE图像诊断充分性的配对绝对一致率范围为0.77至0.86。
临床应用与阅片要点
- 基础前列腺阅片者可依据PI-QUAL评分对mpMRI各序列图像质量进行可重复的评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The Prostate Imaging Quality (PI-QUAL) score is the first step toward image quality assessment in multi-parametric prostate MRI (mpMRI). Previous studies have demonstrated moderate to excellent inter-rater agreement among expert readers; however, there is a need for studies to assess the inter-reader agreement of PI-QUAL scoring in basic prostate readers.
OBJECTIVES: To assess the inter-reader agreement of the PI-QUAL score amongst basic prostate readers on multi-center prostate mpMRI.
METHODS: Five basic prostate readers from different centers assessed the PI-QUAL scores independently using T2-weighted images, diffusion-weighted imaging (DWI) including apparent diffusion coefficient (ADC) maps, and dynamic-contrast-enhanced (DCE) images on mpMRI data obtained from five different centers following Prostate Imaging-Reporting and Data System Version 2.1. The inter-reader agreements amongst radiologists for PI-QUAL were evaluated using weighted Cohen's kappa. Further, the absolute agreements in assessing the diagnostic adequacy of each mpMRI sequence were calculated.
RESULTS: A total of 355 men with a median age of 71 years (IQR, 60-78) were enrolled in the study. The pair-wise kappa scores ranged from 0.656 to 0.786 for the PI-QUAL scores, indicating good inter-reader agreements between the readers. The pair-wise absolute agreements ranged from 0.75 to 0.88 for T2W imaging, from 0.74 to 0.83 for the ADC maps, and from 0.77 to 0.86 for DCE images.
CONCLUSIONS: Basic prostate radiologists from different institutions provided good inter-reader agreements on multi-center data for the PI-QUAL scores.
引用
- Basar, Alis, Seker, et al. Inter-reader agreement of the prostate imaging quality (PI-QUAL) score for basic readers in prostate MRI: A multi-center study. Eur J Radiol. 2023. PMID: 37320883. doi:10.1016/j.ejrad.2023.110923
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。