文献速递腹部技术与安全CT

双层探测器双能CT虚拟单能图像在结直肠癌中的应用:CT诊断能否改善?

Virtual monoenergetic dual-layer dual-energy CT images in colorectal cancer: CT diagnosis could be improved?
PubMed 文献 · Radiol Med · 2023-06-13

回顾性纳入66例组织学证实结直肠癌患者及42例结肠镜无结肠疾病对照,比较双层探测器双能CT常规图像与40-100keV虚拟单能图像。VMI40的信噪比和对比噪声比高于常规CT及其他单能重建;常规CT加用VMI40使两位阅片者诊断结直肠癌的AUC分别从0.875升至0.943、从0.916升至0.954。

要点

  • VMI40的信噪比19.5±7.7、对比噪声比11.8±6.2,高于常规CT及其他单能重建(除VMI50外)。
  • 常规CT加用VMI40后阅片者1的AUC从0.875升至0.943,阅片者2从0.916升至0.954。
  • AUC提升幅度在经验较少的放射科医生中为0.068,大于经验较多者的0.037。

核心结论

  • VMI40显示最高的定量图像参数,且使用VMI40可显著改善结直肠癌的检出诊断性能。

研究设计与样本

  • 回顾性研究,纳入66例组织学证实结直肠癌且具备虚拟单能重建的连续患者,另选42例结肠镜无结肠疾病者作为对照组;采用双层探测器双能CT延迟动脉期常规图像及40至100keV(每10keV递增)虚拟单能重建。

关键影像表现/征象

  • 定量分析显示VMI40的信噪比为19.5±7.7、对比噪声比为11.8±6.2,与常规CT及其他所有虚拟单能重建相比差异有统计学意义(P<0.05),但VMI50除外(P>0.05)。

诊断标准与关键数值

  • 常规CT诊断结直肠癌的AUC在阅片者1为0.875、阅片者2为0.916;加用VMI40后分别升至0.943和0.954(均P<0.05)。
  • AUC提升幅度在经验较少放射科医生为0.068,在经验较多者为0.037。

临床应用与阅片要点

  • 在延迟动脉期加用VMI40重建可提高结直肠癌的诊断AUC,对经验较少的放射科医生提升幅度更大。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare conventional CT images and virtual monoenergetic images (VMI) at dual-layer dual-energy CT (dlDECT) in patients with colorectal cancer (CRC) through quantitative analysis and to investigate the added value of VMI.

MATERIAL AND METHODS: Sixty-six consecutive patients with histologically documented CRC and available VMI reconstructions were retrospectively investigated. Subsequently, forty-two patients, without any colonic disease at colonoscopy, were selected as control group. Conventional CT images and VMI reconstructions at energy levels ranging from 40 (VMI40) to 100 keV (VMI100) in 10 keV increments, were obtained from the late arterial phase. First, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were obtained to select the best VMI reconstruction. Finally, the diagnostic accuracy of conventional CT and VMI40 in late arterial phase was evaluated.

RESULTS: On quantitative analysis, SNR and CNR were higher for VMI40 (19.5 ± 7.7 and 11.8 ± 6.2, respectively) with statistically significant differences compared to conventional CT (P < 0.05) and all the other VMI reconstructions (P < 0.05), except for VMI50 (P > 0.05). The addition of VMI40 to conventional CT images significantly improved the area under the curve (AUC) for the diagnosis of CRC, increasing it from 0.875 to 0.943 for reader 1 (P < 0.05) and from 0.916 to 0.954 for reader 2 (P < 0.05). The improvement was greater in the less experienced radiologist (0.068) compared to the more experienced one (0.037).

CONCLUSION: VMI40 has showed the highest quantitative image parameters. Furthermore, the use of VMI40 can lead to a significant improvement in the diagnostic performance for detecting CRC.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Arico', Trimarchi, Portaluri, et al. Virtual monoenergetic dual-layer dual-energy CT images in colorectal cancer: CT diagnosis could be improved? Radiol Med. 2023. PMID: 37310558. doi:10.1007/s11547-023-01663-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。