文献速递骨肌MR

膝关节MRI与关节镜所见自动关联工作流的开发与实施

Development and Operationalization of an Automated Workflow for Correlation of Knee MRI and Arthroscopy Findings.
PubMed 文献 · J Am Coll Radiol · 2023-06-09

回顾性分析2019—2020年2年内3187例膝关节MRI后6个月内行关节镜手术的患者,通过结构化报告模板和网页电话应用自动提取MRI与手术所见并判定半月板及前交叉韧带撕裂的准确性。自动关联在60%病例中可用,MRI总体诊断准确率93%(内侧半月板92%、外侧半月板89%、前交叉韧带98%),自动与人工判读一致性达99%。

要点

  • 自动关联系统可对膝关节MRI与关节镜所见进行持续、准确的比对。
  • MRI总体诊断准确率93%,内侧半月板92%、外侧半月板89%、前交叉韧带98%。
  • 自动关联与人工判读一致性达99%(内侧半月板98%、外侧半月板100%、前交叉韧带99%)。

核心结论

  • 该自动系统能够对大量MRI检查的影像与手术所见进行准确且持续的关联评估。

研究设计与样本

  • 回顾性分析,纳入2019—2020年2年内行膝关节MRI后6个月内接受关节镜手术的患者3187例(男性1669例,平均年龄47岁),以关节镜为参考标准。

诊断标准与关键数值

  • 以关节镜为参考标准,将MRI所见分为真阳性、真阴性、假阳性、假阴性,MRI总体诊断准确率93%(内侧半月板92%、外侧半月板89%、前交叉韧带98%)。

临床应用与阅片要点

  • 结构化膝关节MRI报告模板结合离散数据提取与手术所见离散录入,可实现影像与手术所见的自动关联并生成每位放射科医师的一致性及个人与组间准确率仪表盘。

局限性

  • 自动关联仅60%的病例可用,而人工复核病例中可与手术关联的比例更高(84%)。
  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: In this study, we sought to establish and evaluate an automated workflow to prospectively capture and correlate knee MRI findings with surgical findings in a large medical center.

METHODS: This retrospective analysis included data from patients who had undergone knee MRI followed by arthroscopic knee surgery within 6 months during a 2-year period (2019-2020). Discrete data were automatically extracted from a structured knee MRI report template implementing pick lists. Operative findings were recorded discretely by surgeons using a custom-built web-based telephone application. MRI findings were classified as true-positive, true-negative, false-positive, or false-negative for medial meniscus (MM), lateral meniscus (LM), and anterior cruciate ligament (ACL) tears, with arthroscopy used as the reference standard. An automated dashboard displaying up-to-date concordance and individual and group accuracy was enabled for each radiologist. Manual correlation between MRI and operative reports was performed on a random sample of 10% of cases for comparison with automatically derived values.

RESULTS: Data from 3,187 patients (1,669 male; mean age, 47 years) were analyzed. Automatic correlation was available for 60% of cases, with an overall MRI diagnostic accuracy of 93% (MM, 92%; LM, 89%; ACL, 98%). In cases reviewed manually, the number of cases that could be correlated with surgery was higher (84%). Concordance between automated and manual review was 99% when both were available (MM, 98%; LM, 100%; ACL, 99%).

CONCLUSION: This automated system was able to accurately and continuously assess correlation between imaging and operative findings for a large number of MRI examinations.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Altahawi, Owens, Caruso, et al. Development and Operationalization of an Automated Workflow for Correlation of Knee MRI and Arthroscopy Findings. J Am Coll Radiol. 2023. PMID: 37302680. doi:10.1016/j.jacr.2023.04.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。