文献速递神经MR

基于脊髓工具箱DeepSeg算法的新型半自动分割流程估计颈椎管面积的验证

Validation of a New Semiautomated Segmentation Pipeline Based on the Spinal Cord Toolbox DeepSeg Algorithm to Estimate the Cervical Canal Area.
PubMed 文献 · AJNR Am J Neuroradiol · 2023-06-08

本研究在8名健康对照和18名多发性硬化患者中,于基线和随访时采集3T脑与颈髓矢状位3D MPRAGE,验证半自动流程测量颈椎管面积与手动分割的一致性(平均Dice相似系数0.90,范围0.73-0.97),并评估1年内测量稳定性及脑与颈髓采集的一致性(组内相关系数分别为0.76和0.77)。结论认为该流程可靠,颈椎管面积随时间稳定,无颈髓序列时可用脑T1WI估计。

要点

  • 半自动流程与手动分割的颈椎管面积一致性极好,平均Dice相似系数0.90(范围0.73-0.97)。
  • 基线与随访扫描的颈椎管面积估计一致性良好,组内相关系数0.76(95%CI 0.44-0.88)。
  • 脑与颈髓MRI获得的颈椎管面积估计一致性良好,组内相关系数0.77(95%CI 0.45-0.90)。

核心结论

  • 所提出的流程是估计颈椎管面积的可靠工具,颈椎管面积是随时间稳定的测量指标,且无颈髓序列时可用脑T1WI估计。

研究设计与样本

  • 纳入8名健康对照和18名多发性硬化患者,于基线和随访时行3T脑与颈髓矢状位3D MPRAGE采集。
  • 以1名评估者的手动分割为参考,用Dice相似系数比较所提出流程的估计值。
  • 比较基线与随访T1WI的颈椎管面积估计,并比较脑与颈髓采集的估计,采用个体和平均组内相关系数。

诊断标准与关键数值

  • 所提出流程与手动颈椎管面积掩膜的平均Dice相似系数为0.90(范围0.73-0.97),一致性极好。
  • 基线与随访扫描的颈椎管面积估计组内相关系数为0.76(95%CI 0.44-0.88),一致性良好。
  • 脑与颈髓MRI的颈椎管面积估计组内相关系数为0.77(95%CI 0.45-0.90),一致性良好。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: As in the brain reserve concept, a larger cervical canal area may also protect against disability. In this context, a semiautomated pipeline has been developed to obtain quantitative estimations of the cervical canal area. The aim of the study was to validate the pipeline, to evaluate the consistency of the cervical canal area measurements during a 1-year period, and to compare cervical canal area estimations obtained from brain and cervical MRI acquisitions.

MATERIALS AND METHODS: Eight healthy controls and 18 patients with MS underwent baseline and follow-up 3T brain and cervical spine sagittal 3D MPRAGE. The cervical canal area was measured in all acquisitions, and estimations obtained with the proposed pipeline were compared with manual segmentations performed by 1 evaluator using the Dice similarity coefficient. The cervical canal area estimations obtained on baseline and follow-up T1WI were compared; brain and cervical cord acquisitions were also compared using the individual and average intraclass correlation coefficients.

RESULTS: The agreement between the manual cervical canal area masks and the masks provided by the proposed pipeline was excellent, with a mean Dice similarity coefficient mean of 0.90 (range, 0.73-0.97). The cervical canal area estimations obtained from baseline and follow-up scans showed a good level of concordance (intraclass correlation coefficient = 0.76; 95% CI, 0.44-0.88); estimations obtained from brain and cervical MRIs also had good agreement (intraclass correlation coefficient = 0.77; 95% CI, 0.45-0.90).

CONCLUSIONS: The proposed pipeline is a reliable tool to estimate the cervical canal area. The cervical canal area is a stable measure across time; moreover, when cervical sequences are not available, the cervical canal area could be estimated using brain T1WI.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Mongay-Ochoa, Pareto, Alberich, et al. Validation of a New Semiautomated Segmentation Pipeline Based on the Spinal Cord Toolbox DeepSeg Algorithm to Estimate the Cervical Canal Area. AJNR Am J Neuroradiol. 2023. PMID: 37290816. doi:10.3174/ajnr.A7899

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。