文献速递神经MR

脑部成像中深度学习加速液体衰减反转恢复序列的图像重建:缩短采集时间并提高图像质量

Deep Learning Accelerated Image Reconstruction of Fluid-Attenuated Inversion Recovery Sequence in Brain Imaging: Reduction of Acquisition Time and Improvement of Image Quality.
PubMed 文献 · Acad Radiol · 2023-06-04

本研究回顾性纳入70例连续接受脑部MRI分期检查的患者,比较深度学习加速FLAIR(FLAIRDLR)与传统FLAIR(FLAIRS)的图像质量与诊断信心。FLAIRDLR采用更高并行成像加速因子(从2提高到4),采集时间从2分40秒缩短至1分39秒(降低38%)。结果显示FLAIRDLR图像噪声更少,锐利度、病灶检出和整体图像质量评分更高(中位评分4 vs 3,P<.001),两位阅片者在68/70例中偏好FLAIRDLR。

要点

  • FLAIRDLR采集时间1分39秒,较FLAIRS的2分40秒缩短38%。
  • FLAIRDLR图像噪声显著少于FLAIRS(P<.001和P<.05)。
  • FLAIRDLR锐利度与病灶检出中位评分4 vs FLAIRS 3(P<.001)。

核心结论

  • 深度学习FLAIR脑成像可行性得到证实,检查时间较标准FLAIR额外减少38%,并在图像质量、噪声降低和病灶边界显示方面有所改善。

研究设计与样本

  • 单中心回顾性研究,连续纳入70例接受脑部MRI分期检查的患者,比较FLAIRDLR与FLAIRS序列。

关键影像表现/征象

  • FLAIRDLR图像噪声显著少于FLAIRS,P值分别为<.001和<.05。
  • FLAIRDLR图像锐利度和病灶检出能力评分高于FLAIRS,中位评分4 vs 3(两位阅片者P均<.001)。
  • FLAIRDLR整体图像质量评分优于FLAIRS,中位评分4 vs 3(两位阅片者P均<.001)。

诊断标准与关键数值

  • 采用1–4分Likert量表评估锐利度、病灶边界、伪影、整体图像质量和诊断信心,4分为最佳。

临床应用与阅片要点

  • 两位专科神经放射科医生在68/70例中偏好FLAIRDLR图像。
  • FLAIRDLR使用与FLAIRS相同的MRI采集参数,仅并行成像加速因子从2提高至4。

局限性

  • 本研究为单中心回顾性研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Fluid-attenuated inversion recovery (FLAIR) imaging is playing an increasingly significant role in the detection of brain metastases with a concomitant increase in the number of magnetic resonance imaging (MRI) examinations. Therefore, the purpose of this study was to investigate the impact on image quality and diagnostic confidence of an innovative deep learning-based accelerated FLAIR (FLAIRDLR) sequence of the brain compared to conventional (standard) FLAIR (FLAIRS) imaging.

MATERIALS AND METHODS: Seventy consecutive patients with staging cerebral MRIs were retrospectively enrolled in this single-center study. The FLAIRDLR was conducted using the same MRI acquisition parameters as the FLAIRS sequence, except for a higher acceleration factor for parallel imaging (from 2 to 4), which resulted in a shorter acquisition time of 1:39 minute instead of 2:40 minutes (-38%). Two specialized neuroradiologists evaluated the imaging datasets using a Likert scale that ranged from 1 to 4, with 4 indicating the best score for the following parameters: sharpness, lesion demarcation, artifacts, overall image quality, and diagnostic confidence. Additionally, the image preference of the readers and the interreader agreement were assessed.

RESULTS: The average age of the patients was 63 ± 11years. FLAIRDLR exhibited significantly less image noise than FLAIRS, with P-values of< .001 and< .05, respectively. The sharpness of the images and the ability to detect lesions were rated higher in FLAIRDLR, with a median score of 4 compared to a median score of 3 in FLAIRS (P-values of<.001 for both readers). In terms of overall image quality, FLAIRDLR was rated superior to FLAIRS, with a median score of 4 vs 3 (P-values of<.001 for both readers). Both readers preferred FLAIRDLR in 68/70 cases.

CONCLUSION: The feasibility of deep learning FLAIR brain imaging was shown with additional 38% reduction in examination time compared to standard FLAIR imaging. Furthermore, this technique has shown improvement in image quality, noise reduction, and lesion demarcation.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Estler, Hauser, Mengel, et al. Deep Learning Accelerated Image Reconstruction of Fluid-Attenuated Inversion Recovery Sequence in Brain Imaging: Reduction of Acquisition Time and Improvement of Image Quality. Acad Radiol. 2023. PMID: 37280126. doi:10.1016/j.acra.2023.05.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。