文献速递神经外周血管MRDSA

支架辅助弹簧圈栓塞治疗颅内动脉瘤:四维超短回波时间MR血管成像评估

Intracranial aneurysms treated with stent-assisted coil embolization: evaluation with four-dimensional ultrashort-TE MR angiography.
PubMed 文献 · Eur Radiol · 2023-06-07

本研究纳入31例连续接受支架辅助弹簧圈栓塞治疗的颅内动脉瘤患者,在3 T下进行四维超短回波时间MR血管成像(4D mUTE-MRA)与DSA检查。4D mUTE-MRA与DSA在动脉瘤闭塞状态评估上具有 excellent 的观察者间及方法间一致性(κ=0.96和κ=0.92)。支架内血流显示在单支架较多个支架、开孔型支架较闭孔型支架评分更高。

要点

  • 4D mUTE-MRA与DSA评估动脉瘤闭塞状态的一致性极佳,观察者间κ=0.96,方法间κ=0.92。
  • 支架内血流可视化在单支架优于多支架(p<.001),开孔型优于闭孔型(p<.01)。
  • 4D mUTE-MRA可提供栓塞动脉瘤及支架载瘤动脉远端动脉的血流动力学信息。

核心结论

  • 4D mUTE-MRA是一种具有高空间和时间分辨率的工具,可用于评估支架辅助弹簧圈栓塞治疗的颅内动脉瘤。

研究设计与样本

  • 研究纳入31例连续接受支架辅助弹簧圈栓塞治疗的颅内动脉瘤患者,在3 T下进行4D mUTE-MRA和DSA检查;4D mUTE-MRA每200 ms获得5幅动态MRA图像,空间分辨率为0.5×0.5×0.5 mm³;以DSA为参考标准。

关键影像表现/征象

  • 4D mUTE-MRA上支架内血流的平均评分在单支架高于多个支架(p<.001),在开孔型支架高于闭孔型支架(p<.01)。
  • DSA显示10个动脉瘤为完全闭塞,14个为残留瘤颈,7个为残留动脉瘤。
  • 4D mUTE-MRA可显示栓塞动脉瘤及支架载瘤动脉远端动脉的血流动力学信息。

诊断标准与关键数值

  • 动脉瘤闭塞状态分为完全闭塞、残留瘤颈和残留动脉瘤,4D mUTE-MRA与DSA的方法间一致性κ=0.92,观察者间一致性κ=0.96。
  • 支架内血流采用4分制评分(1分=不可见,4分=极好)。

临床应用与阅片要点

  • 4D mUTE-MRA与DSA在评估支架辅助弹簧圈栓塞后动脉瘤闭塞状态方面具有极佳的一致性。
  • 4D mUTE-MRA对单支架或开孔型支架的血流显示较好至极好。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: As a novel follow-up method for intracranial aneurysms treated with stent-assisted coil embolization (SACE), we developed four-dimensional magnetic resonance angiography (MRA) with minimized acoustic noise utilizing ultrashort-echo time (4D mUTE-MRA). We aimed to assess whether 4D mUTE-MRA is useful for the evaluation of intracranial aneurysms treated with SACE.

METHODS: This study included 31 consecutive patients with intracranial aneurysm treated with SACE who underwent 4D mUTE-MRA at 3 T and digital subtraction angiography (DSA). For 4D mUTE-MRA, five dynamic MRA images with a spatial resolution of 0.5 × 0.5 × 0.5 mm3 were obtained every 200 ms. Two readers independently reviewed the 4D mUTE-MRA images to evaluate the aneurysm occlusion status (total occlusion, residual neck, and residual aneurysm) and the flow in the stent using a 4-point scale (from 1 [not visible] to 4 [excellent]). The interobserver and intermodality agreement was assessed using κ statistics.

RESULTS: On DSA images, 10 aneurysms were classified as total occlusion, 14 as residual neck, and 7 as residual aneurysm. In terms of aneurysm occlusion status, the intermodality and interobserver agreement was excellent (κ = 0.92 and κ = 0.96, respectively). For the flow in the stents on 4D mUTE-MRA, the mean score was significantly higher for single stents than multiple stents (p < .001) and for open-cell type stents than closed-cell type (p < .01).

CONCLUSIONS: 4D mUTE-MRA is a useful tool with a high spatial and temporal resolution for the evaluation of intracranial aneurysms treated with SACE.

KEY POINTS: • In the evaluation of intracranial aneurysms treated with SACE on 4D mUTE-MRA and DSA, the intermodality and interobserver agreement in aneurysm occlusion status was excellent. • 4D mUTE-MRA shows good to excellent visualization of flow in the stents, especially for cases treated with a single or open-cell stent. • 4D mUTE-MRA can provide hemodynamic information related to embolized aneurysms and the distal arteries to stented parent arteries.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Uetani, Kitajima, Ohmori, et al. Intracranial aneurysms treated with stent-assisted coil embolization: evaluation with four-dimensional ultrashort-TE MR angiography. Eur Radiol. 2023. PMID: 37284863. doi:10.1007/s00330-023-09755-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。