文献速递腹部介入US

结直肠癌肝转移术中高强度聚焦超声:一项前瞻性消融并切除研究

Intra-operative High-Intensity Focused Ultrasound in Patients With Colorectal Liver Metastases: A Prospective Ablate-and-Resect Study.
PubMed 文献 · Ultrasound Med Biol · 2023-05-31

这项前瞻性单中心II期消融并切除研究评估了术中环形技术HIFU探头治疗小于30 mm结直肠癌肝转移的可行性和有效性。15例患者共24个病灶接受治疗,23个(95.8%)成功达到大于5 mm安全边界,消融平均耗时370秒,消融灶呈扁球形,平均长轴44.3±6.1 mm、最短轴35.9±6.7 mm,病理平均转移灶直径12.2±4.8 mm,无肝外组织损伤。

要点

  • 术中HIFU可在约6分钟内对大病灶实现安全消融,消融边界大于5 mm。
  • 消融灶呈扁球形,平均长轴44.3 mm、最短轴35.9 mm,病理灶平均12.2 mm。
  • 所有消融均在计划切除的肝区内进行,以避免丧失治愈机会。

关键影像表现/征象

  • HIFU消融灶呈扁球形,平均长轴44.3±6.1 mm,平均最短轴35.9±6.7 mm。
  • 病理检查示接受治疗的转移灶平均直径12.2±4.8 mm。
  • 24个结直肠癌肝转移灶中23个(95.8%)成功消融,无肝外组织损伤。

诊断标准与关键数值

  • 目标病灶为小于30 mm的结直肠癌肝转移。
  • 成功消融标准为达到大于5 mm安全边界,24个病灶中23个(95.8%)达到。
  • HIFU消融时间为370秒。

临床应用与阅片要点

  • 该技术适用于计划切除肝区内的结直肠癌肝转移,消融后行病理验证安全边界。
  • 术中实时引导下可产生较大范围消融,需注意消融灶扁球形形态对边界评估的影响。
  • 研究显示无肝外组织损伤,提示术中HIFU定位具有较好的安全性。

局限性

  • 单中心、小样本(15例患者、24个病灶)II期研究。
  • 所有消融均在计划切除肝区内进行,无法评估对非切除区肿瘤的长期局部控制。
  • 缺乏长期随访肿瘤学结局数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: High-intensity focused ultrasound (HIFU) is a recent, non-ionizing and non-invasive technology of focal destruction. Independence from the heat-sink effect of blood flow makes HIFU an interesting technique for focal ablation of liver tumors. Current available technology is based on extracorporeal treatment that limits use of HIFU for the treatment of liver tumors, as elementary ablations are small and must be juxtaposed to treat tumors, resulting in long-duration treatment. We developed an HIFU probe with toroidal technology, which increases the volume of ablation, for intra-operative use, and we assessed the feasibility and efficacy of this device in patients with colorectal liver metastasis (CLM) measuring less than 30 mm.

METHODS: This study was an ablate-and-resect, prospective, single-center, phase II study. All ablations were performed in the area of liver scheduled for liver resection to avoid loss of chance of recovery. The primary objective was to ablate CLM with safety margins (>5 mm).

RESULTS: Between May 2014 and July 2020, 15 patients were enrolled and 24 CLM were targeted. The HIFU ablation time was 370 s. In total, 23 of 24 CLM were successfully treated (95.8%). No damage occurred to extrahepatic tissues. HIFU ablations were oblate shaped with an average long axis of 44.3 ± 6.1 mm and an average shortest axis of 35.9 ± 6.7 mm. On pathological examination, the average diameter of the treated metastasis was 12.2 ± 4.8 mm.

CONCLUSION: Intra-operative HIFU can safely and accurately produce large ablations in 6 min with real-time guidance (ClinicalTrials.gov identifier: NCT01489787).

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Dupré, Rivoire, Metzger, et al. Intra-operative High-Intensity Focused Ultrasound in Patients With Colorectal Liver Metastases: A Prospective Ablate-and-Resect Study. Ultrasound Med Biol. 2023. PMID: 37268553. doi:10.1016/j.ultrasmedbio.2023.04.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。