心脏计算机断层扫描定量心肌细胞外容积分数:系统综述与荟萃分析
本荟萃分析纳入13项研究共383例患者,评估CT与心脏磁共振(CMR)定量心肌细胞外容积(ECV)的相关性和一致性。CT与CMR来源的ECV相关性极好(平均相关系数0.90,95%CI 0.86-0.95),汇总平均差异为0.96%(95%CI 0.14%-1.78%)。双能CT的汇总相关性显著高于单能CT(0.94 vs 0.87,P=0.01),但两者平均差异无显著差异(P=0.85);纳入研究总体质量偏低,需更大规模前瞻性研究验证。
要点
- CT来源ECV与CMR来源ECV相关性极好,平均相关系数0.90(95%CI 0.86-0.95)。
- CT与CMR的ECV汇总平均差异为0.96%(95%CI 0.14%-1.78%),小于1%。
- 双能CT的汇总相关性显著高于单能CT(0.94 vs 0.87,P=0.01)。
核心结论
- CT来源ECV与CMR来源ECV相关性极好且平均差异小于1%;但纳入研究总体质量偏低,需更大规模前瞻性研究检验CT来源ECV的准确性及诊断和预后价值。
研究设计与样本
- 系统综述与荟萃分析,检索PubMed和Web of Science,纳入13项研究共383例患者,以CMR为参考标准,采用限制性最大似然估计的随机效应模型汇总相关系数和平均差异。
诊断标准与关键数值
- CT与CMR来源ECV总体平均相关系数0.90(95%CI 0.86-0.95)。
- CT与CMR来源ECV汇总平均差异0.96%(95%CI 0.14%-1.78%)。
- 双能CT汇总相关系数0.94(95%CI 0.91-0.98) vs 单能CT 0.87(95%CI 0.80-0.94),双能CT较单能CT升高,P=0.01。
- 单能CT与双能CT的汇总平均差异无显著差异(P=0.85)。
局限性
- 纳入研究的总体质量偏低。
- 需要更大规模的前瞻性研究来检验CT来源ECV的准确性及诊断和预后价值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Extracellular volume (ECV) is a quantitative measure of extracellular compartment expansion, and an increase in ECV is a marker of myocardial fibrosis. Although cardiac magnetic resonance (CMR) is considered the standard imaging tool for ECV quantification, cardiac computed tomography (CT) has also been used for ECV assessment.
OBJECTIVES: The aim of this meta-analysis was to evaluate the correlation and agreement in the quantification of myocardial ECV by CT and CMR.
METHODS: PubMed and Web of Science were searched for relevant publications reporting on the use of CT for ECV quantification compared with CMR as the reference standard. The authors employed a meta-analysis using the restricted maximum-likelihood estimator with a random-effects method to estimate summary correlation and mean difference. A subgroup analysis was performed to compare the correlation and mean differences between single-energy CT (SECT) and dual-energy CT (DECT) techniques for the ECV quantification.
RESULTS: Of 435 papers, 13 studies comprising 383 patients were identified. The mean age range was 57.3 to 82 years, and 65% of patients were male. Overall, there was an excellent correlation between CT-derived ECV and CMR-derived ECV (mean: 0.90 [95% CI: 0.86-0.95]). The pooled mean difference between CT and CMR was 0.96% (95% CI: 0.14%-1.78%). Seven studies reported correlation values using SECT, and 4 studies reported those using DECT. The pooled correlation from studies utilizing DECT for ECV quantification was significantly higher compared with those with SECT (mean: 0.94 [95% CI: 0.91-0.98] vs 0.87 [95% CI: 0.80-0.94], respectively; P = 0.01). There was no significant difference in pooled mean differences between SECT vs DECT (P = 0.85).
CONCLUSIONS: CT-derived ECV showed an excellent correlation and mean difference of <1% with CMR-derived ECV. However, the overall quality of the included studies was low, and larger, prospective studies are needed to examine the accuracy and diagnostic and prognostic utility of CT-derived ECV.
引用
- Han, Lin, Kuronuma, et al. Cardiac Computed Tomography for Quantification of Myocardial Extracellular Volume Fraction: A Systematic Review and Meta-Analysis. JACC Cardiovasc Imaging. 2023. PMID: 37269267. doi:10.1016/j.jcmg.2023.03.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。