文献速递心血管CTDSA

基于冠状动脉CT血管成像的DEEPVESSEL血流储备分数与定量斑块分析对主要不良心脏事件的预测价值

Predictive value of DEEPVESSEL-fractional flow reserve and quantitative plaque analysis based on coronary CT angiography for major adverse cardiac events.
PubMed 文献 · Clin Radiol · 2023-05-13

回顾性纳入58例连续患者的69支血管,评估基于冠状动脉CT血管成像的DEEPVESSEL血流储备分数(DVFFR)与定量斑块分析对主要不良心脏事件(MACE)的预测价值。DVFFR与有创FFR高度相关(R=0.728),识别异常血流动力学血管的AUC为0.984;DVFFR≤0.8、狭窄分级、总斑块负荷、非钙化斑块负荷及病变长度是多变量分析中MACE的预测因子,联合上述独立危险因素对MACE的预测AUC为0.888。

要点

  • DVFFR与有创FFR高度相关(R=0.728),识别异常血流动力学血管AUC达0.984。
  • DVFFR≤0.8、狭窄分级、总斑块负荷、非钙化斑块负荷及病变长度是多变量分析中MACE的预测因子。
  • 联合上述独立危险因素对MACE的预测价值最高,AUC为0.888。

核心结论

  • DVFFR与FFR高度相关且诊断准确性令人满意,DVFFR联合斑块分析指标对MACE具有有价值的预测作用。

研究设计与样本

  • 回顾性研究,纳入58例连续患者的69支血管,患者接受冠状动脉造影(CAG)并计算DVFFR,分为MACE阳性组与MACE阴性组;DVFFR测量基于CAG前采集的CCTA图像,FFR或DVFFR值≤0.80定义为血流动力学显著;CCTA图像用自动化软件定量分析获得总斑块体积(TPV)与负荷(TPB)、钙化斑块体积(CPV)与负荷(CPB)、非钙化斑块体积(NCPV)与负荷(NCPB)、低衰减斑块(LAP)、最小管腔面积(MLA)、狭窄分级(SG)及病变长度(LL);采用单变量与多变量逻辑回归、相关分析及ROC分析进行统计学分析。

诊断标准与关键数值

  • FFR或DVFFR值≤0.80视为血流动力学显著;DVFFR与有创FFR高度相关(R=0.728),Bland-Altman图显示两者在每支血管水平一致性良好(95% CI:-0.109-0.087);DVFFR识别异常血流动力学血管的AUC为0.984;多变量分析中MACE的预测因子包括DVFFR≤0.8、SG、TPB、NCPB及LL;上述独立危险因素联合预测MACE的AUC为0.888。

临床应用与阅片要点

  • DVFFR≤0.8、狭窄分级、总斑块负荷、非钙化斑块负荷及病变长度是多变量分析中MACE的预测因子。
  • 联合上述独立危险因素对MACE的预测价值最高(AUC:0.888)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To investigate the predictive value of the combination of DEEPVESSEL-fractional flow reserve (DVFFR) and quantitative plaque analysis using coronary computed tomographic angiography (CCTA) for major adverse cardiac events (MACE).

METHOD: In this retrospective study, data from 69 vessels from 58 consecutive patients were collected. These patients who underwent coronary angiography (CAG) with DVFFR were divided into MACE-positive and MACE-negative groups. DVFFR measurements were obtained from CCTA images acquired before CAG, and an FFR or DVFFR value ≤ 0.80 was considered haemodynamically significant. CCTA images were analysed quantitatively using automated software to obtain the following indices: total plaque volume (TPV) and burden (TPB), calcified plaque volume (CPV) and burden (CPB), non-calcified plaque volume (NCPV) and burden (NCPB), low-attenuation plaque (LAP), minimum lumen area (MLA), stenosis grade (SG) and lesion length (LL). Univariate and multivariate logistic regression, correlation, and receiver operating characteristic (ROC) analyses were used for statistical analysis.

RESULTS: DVFFR was highly correlated with invasive FFR (R=0.728), and the Bland-Altman plot showed good agreement between DVFFR and FFR (95% CI: -0.109-0.087) on a per-vessel level. DVFFR showed a high diagnostic performance in identifying abnormal haemodynamic vessels, with an area under the ROC curve (AUC) of 0.984. In multivariate analysis, the following biomarkers were predictors of MACE: DVFFR ≤ 0.8, SG, TPB, NCPB, and LL values. The combination of the above independent risk factors yielded the most valuable prediction for MACE (AUC:0.888).

CONCLUSIONS: DVFFR was highly correlated with FFR with satisfactory diagnostic accuracy. DVFFR, together with plaque analysis indices, yielded valuable predictions for MACE.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Liu, Li, Bai, et al. Predictive value of DEEPVESSEL-fractional flow reserve and quantitative plaque analysis based on coronary CT angiography for major adverse cardiac events. Clin Radiol. 2023. PMID: 37258332. doi:10.1016/j.crad.2023.04.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。