文献速递技术与安全US

麻醉载气对大鼠静脉注射磷脂氧微泡体内循环时间的影响

Effect of Anesthetic Carrier Gas on In Vivo Circulation Times of Intravenously Administered Phospholipid Oxygen Microbubbles in Rats.
PubMed 文献 · Ultrasound Med Biol · 2023-05-27

研究在大鼠纵向肾脏超声成像中,比较吸入异氟烷麻醉时以纯氧或医用空气作为载气对静脉注射磷脂氧微泡循环时间的影响。结果显示氧微泡在对比特异性成像下高度可见,且动物呼吸纯氧时氧微泡从循环中消失的速度显著快于呼吸医用空气时,作者认为这可能与氮气反扩散改变气泡核心气体组成有关,并提示呼吸空气麻醉时氧微泡的表观循环持久性可能并不反映氧输送。

要点

  • 氧微泡在对比特异性超声成像下高度可见,可用于纵向肾脏成像评估循环时间。
  • 动物呼吸纯氧时氧微泡从循环中消失的速度显著快于呼吸医用空气时。
  • 作者认为呼吸空气麻醉时氧微泡的表观循环持久性可能并不反映氧输送。

核心结论

  • 氧微泡在对比特异性成像下高度可见,且呼吸纯氧的动物中氧微泡从循环中消失的速度显著快于呼吸医用空气的动物,作者认为这可能与氮气反扩散改变气泡核心气体组成有关,并提示呼吸空气麻醉时氧微泡的表观循环持久性可能并不反映氧输送。

研究设计与样本

  • 大鼠研究,比较吸入异氟烷麻醉下以纯氧或医用空气作为载气时静脉注射磷脂氧微泡的循环时间,循环时间由纵向肾脏超声成像获得的图像强度推导。

关键影像表现/征象

  • 氧微泡在对比特异性超声成像下高度可见。
  • 呼吸空气与呼吸纯氧的动物之间观察到明显的信号增强和持续时间差异。

诊断标准与关键数值

  • 循环时间由纵向肾脏超声成像获得的图像强度推导。
  • 氧微泡在呼吸纯氧的动物中从循环消失的速度显著快于呼吸医用空气的动物。

临床应用与阅片要点

  • 作者认为呼吸空气麻醉时氧微泡的表观循环持久性可能并不反映氧输送。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: For the treatment of tumor hypoxia, microbubbles comprising oxygen as a majority component of the gas core with a stabilizing shell may be used to deliver and release oxygen locally at the tumor site through ultrasound destruction. Previous work has revealed differences in circulation half-life in vivo for perfluorocarbon-filled microbubbles, typically used as ultrasound imaging contrast agents, as a function of anesthetic carrier gas. These differences in circulation time in vivo were likely due to gas diffusion as a function of anesthetic carrier gas, among other variables. This work has motivated studies to evaluate the effect of anesthetic carrier gas on oxygen microbubble circulation dynamics.

METHODS: Circulation time for oxygen microbubbles was derived from ultrasound image intensity obtained during longitudinal kidney imaging. Studies were constructed for rats anesthetized on inhaled isoflurane with either pure oxygen or medical air as the anesthetic carrier gas.

RESULTS: Results indicated that oxygen microbubbles were highly visible via contrast-specific imaging. Marked signal enhancement and duration differences were observed between animals breathing air and oxygen. Perhaps counterintuitively, oxygen microbubbles disappeared from circulation significantly faster when the animals were breathing pure oxygen compared with medical air. This may be explained by nitrogen counterdiffusion from blood into the bubble, effectively changing the gas composition of the core, as has been observed in perfluorocarbon core microbubbles.

CONCLUSION: Our findings suggest that the apparent longevity and persistence of oxygen microbubbles in circulation may not be reflective of oxygen delivery when the animal is anesthetized breathing air.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Durham, Upadhyay, Navarro-Becerra, et al. Effect of Anesthetic Carrier Gas on In Vivo Circulation Times of Intravenously Administered Phospholipid Oxygen Microbubbles in Rats. Ultrasound Med Biol. 2023. PMID: 37246050. doi:10.1016/j.ultrasmedbio.2023.04.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。