LI-RADS v2018 在钆塞酸增强 MRI 上鉴别癌栓与良性血栓的观察者间一致性与准确性
回顾性纳入98例有肝细胞癌风险且Gx-MRI报告静脉闭塞的患者(103处闭塞,58处癌栓、45处良性血栓),5名放射科医师独立应用LI-RADS癌栓标准(静脉内强化软组织)分类,观察者间ICC为0.63,敏感度0.62-0.93、特异度0.87-1.00;基于共识特征构建的多特征模型经交叉验证后未提高敏感度或特异度(P=0.23和0.25)。
要点
- LI-RADS癌栓标准(静脉内强化软组织)在Gx-MRI上观察者间一致性为ICC 0.63
- 该标准敏感度因阅片者而异为0.62-0.93,特异度为0.87-1.00
- 基于LI-RADS标准加一个提示特征的多特征模型经交叉验证未提高诊断效能
核心结论
- 使用Gx-MRI时,LI-RADS癌栓标准提供中等观察者间一致性、可变敏感度和高特异度来鉴别癌栓与良性血栓;交叉验证的多特征模型未提高诊断性能。
研究设计与样本
- 回顾性识别连续患者,纳入98例有肝细胞癌风险且Gx-MRI报告静脉闭塞者(103处闭塞),5名放射科医师独立分类,参考标准未在原文明确报告。
关键影像表现/征象
- 癌栓表现为静脉内强化软组织,良性血栓无此征象。
- 闭塞或遮盖的静脉与恶性实质肿块相连是LI-RADS提示特征之一。
诊断标准与关键数值
- LI-RADS癌栓标准(静脉内强化软组织)观察者间ICC为0.63。
- LI-RADS标准敏感度因阅片者而异为0.62-0.93,特异度为0.87-1.00。
- 多特征模型纳入LI-RADS标准和一个LI-RADS提示特征(闭塞或遮盖的静脉与恶性实质肿块相连)。
- 交叉验证后多特征模型与LI-RADS标准相比敏感度P=0.23、特异度P=0.25,未达统计学显著。
临床应用与阅片要点
- 阅片时可应用LI-RADS癌栓标准(静脉内强化软组织)鉴别癌栓与良性血栓。
- 注意该标准敏感度因阅片者而异(0.62-0.93),特异度较高(0.87-1.00)。
- 闭塞或遮盖的静脉与恶性实质肿块相连可作为提示癌栓的辅助特征。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess inter-observer agreement and accuracy of LI-RADS v2018 for differentiating tumor in vein (TIV) from bland thrombus on gadoxetic acid-enhanced magnetic resonance imaging (Gx-MRI). Secondarily, to determine whether a multi-feature model improves accuracy compared to LI-RADS.
METHODS: We retrospectively identified consecutive patients at risk for hepatocellular carcinoma with venous occlusion(s) reported on Gx-MRI. Five radiologists independently classified each occlusion as TIV or bland thrombus using the LI-RADS TIV criterion (enhancing soft tissue in vein). They also evaluated imaging features suggestive of TIV or bland thrombus. Intra-class correlation coefficient (ICC) was calculated for individual features. A multi-feature model was developed based on consensus scores of features with > 5% consensus prevalence and > 0.40 ICC. Sensitivity and specificity of the LI-RADS criterion and of the cross-validated multi-feature model were compared.
RESULTS: Ninety-eight patients with 103 venous occlusions (58 TIV, 45 bland thrombus) were included. The LI-RADS criterion provided 0.63 ICC and, depending on the reader, 0.62-0.93 sensitivity and 0.87-1.00 specificity. Five other features had > 5% consensus prevalence and > 0.40 ICC, including three LI-RADS suggestive features and two non-LI-RADS features. The optimal multi-feature model incorporated the LI-RADS criterion and one LI-RADS suggestive feature (occluded or obscured vein contiguous with malignant parenchymal mass). After cross-validation, the multi-feature model did not improve sensitivity or specificity compared to the LI-RADS criterion (P = 0.23 and 0.25, respectively).
CONCLUSION: Using Gx-MRI, the LI-RADS criterion for TIV provides substantial inter-observer agreement, variable sensitivity, and high specificity for differentiating TIV from bland thrombus. A cross-validated multi-feature model did not improve diagnostic performance.
引用
- Ichikawa, Sirlin, Cunha, et al. Inter-observer agreement and accuracy of LI-RADS v2018 for differentiating tumor in vein from bland thrombus using gadoxetic acid-enhanced magnetic resonance imaging. Abdom Radiol (NY). 2023. PMID: 37246973. doi:10.1007/s00261-023-03964-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。