利用深度学习在儿童患者中通过99mTc-DMSA SPECT区分正常与异常肾脏
回顾性分析301例儿童99mTc-DMSA肾SPECT检查,按261/20/20随机分为训练、验证和测试集,分别用3D SPECT图像、2D最大强度投影(MIP)和2.5D MIP训练深度学习模型区分正常与异常肾脏,以两名核医学医师共识读片为参考标准。2.5D MIP模型表现最优,测试集准确率92.5%、敏感度90%、特异度95%。
要点
- 2.5D MIP(横断、矢状、冠状位)训练的深度学习模型区分正常与异常肾脏的准确率达92.5%。
- 该模型敏感度90%、特异度95%,优于3D SPECT和2D MIP训练的模型。
- 研究提示深度学习有潜力利用99mTc-DMSA SPECT区分儿童正常与异常肾脏。
核心结论
- 实验结果表明,深度学习有潜力利用99mTc-DMSA SPECT成像区分儿童正常与异常肾脏。
研究设计与样本
- 回顾性研究,共复习301例99mTc-DMSA肾SPECT检查,患者随机分为训练集261例、验证集20例和测试集20例;深度学习模型分别基于3D SPECT图像、2D最大强度投影(MIP)和2.5D MIP(横断、矢状、冠状位)训练,以两名核医学医师共识读片结果为参考标准。
关键影像表现/征象
- 2.5D MIP训练的深度学习模型表现优于3D SPECT图像或2D MIP训练的模型。
诊断标准与关键数值
- 2.5D模型区分正常与异常肾脏的准确率为92.5%,敏感度为90%,特异度为95%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To investigate the feasibility of using deep learning (DL) to differentiate normal from abnormal (or scarred) kidneys using technetium-99m dimercaptosuccinic acid (99mTc-DMSA) single-photon-emission computed tomography (SPECT) in paediatric patients.
MATERIAL AND METHODS: Three hundred and one 99mTc-DMSA renal SPECT examinations were reviewed retrospectively. The 301 patients were split randomly into 261, 20, and 20 for training, validation, and testing data, respectively. The DL model was trained using three-dimensional (3D) SPECT images, two-dimensional (2D) maximum intensity projections (MIPs), and 2.5-dimensional (2.5D) MIPs (i.e., transverse, sagittal, and coronal views). Each DL model was trained to determine renal SPECT images into either normal or abnormal. Consensus reading results by two nuclear medicine physicians served as the reference standard.
RESULTS: The DL model trained by 2.5D MIPs outperformed that trained by either 3D SPECT images or 2D MIPs. The accuracy, sensitivity, and specificity of the 2.5D model for the differentiation between normal and abnormal kidneys were 92.5%, 90% and 95%, respectively.
CONCLUSION: The experimental results suggest that DL has the potential to differentiate normal from abnormal kidneys in children using 99mTc-DMSA SPECT imaging.
引用
- Lin, Chang, Chiu, et al. Differentiation between normal and abnormal kidneys using 99mTc-DMSA SPECT with deep learning in paediatric patients. Clin Radiol. 2023. PMID: 37244824. doi:10.1016/j.crad.2023.04.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。