基于BI-RADS描述符与表观扩散系数改善乳腺病变鉴别诊断:与Kaiser评分对比的多参数MRI分析
研究纳入341个乳腺病变(161恶性、180良性),利用BI-RADS描述符、临床特征和ADC构建列线图,并与Kaiser评分对比。两种多变量模型AUC分别为0.957和0.958,均显著高于Kaiser评分的0.919(均P<0.001);在相同敏感度95.7%下,特异度分别提高5.56%(P=0.076)和6.11%(P=0.035)。作者认为模型可能减少不必要的活检,但需外部验证。
要点
- 高龄、根征、平台型及流出型TIC、不均匀内部强化、瘤周水肿和ADC与恶性独立相关。
- ADC以1.30×10⁻³ mm²/s为界值构建的列线图AUC为0.958(95%CI 0.931-0.976),高于Kaiser评分的0.919(P<0.001)。
- 相同敏感度95.7%下,两模型特异度较Kaiser评分分别提高5.56%(P=0.076)和6.11%(P=0.035)。
核心结论
- 整合MRI特征(根征、TIC、边缘、内部强化、水肿)、定量ADC值和患者年龄的模型较Kaiser评分诊断性能提高,可能避免更多不必要的活检,但需进一步外部验证。
研究设计与样本
- 共纳入341个病变(161个恶性、180个良性),回顾临床数据与影像特征,行单变量和多变量logistic回归确定独立预测变量。
关键影像表现/征象
- 根征、平台型及流出型时间-强度曲线、不均匀内部强化、瘤周水肿为与恶性独立相关的MRI征象。
诊断标准与关键数值
- ADC以1.30×10⁻³ mm²/s为界值二分类后纳入模型构建。
- 连续ADC模型AUC为0.957(95%CI 0.929-0.976),二分类ADC模型AUC为0.958(95%CI 0.931-0.976),Kaiser评分AUC为0.919(95%CI 0.885-0.946),两模型均显著高于Kaiser评分(均P<0.001)。
- 在相同敏感度95.7%下,两模型特异度较Kaiser评分分别提高5.56%(P=0.076)和6.11%(P=0.035)。
局限性
- 作者指出需进一步外部验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To develop the nomogram utilizing the American College of Radiology BI-RADS descriptors, clinical features, and apparent diffusion coefficient (ADC) to differentiate benign from malignant breast lesions.
MATERIALS AND METHODS: A total of 341 lesions (161 malignant and 180 benign) were included. Clinical data and imaging features were reviewed. Univariable and multivariable logistic regression analyses were performed to determine the independent variables. ADC as a continuous or classified into binary form with a cutoff value of 1.30 × 10-3 mm2/s, incorporated other independent predictors to construct two nomograms, respectively. Receiver operating curve and calibration plot was employed to test the models' discriminative ability. The diagnostic performance between the developed model and the Kaiser score (KS) was also compared.
RESULTS: In both models, high patient age, the presence of root sign, time-intensity curves (TICs) types (plateau and washout), heterogenous internal enhancement, the presence of peritumoral edema, and ADC were independently associated with malignancy. The AUCs of two multivariable models (AUC, 0.957; 95% CI: 0.929-0.976 and AUC, 0.958; 95% CI: 0.931-0.976) were significantly higher than that of the KS (AUC, 0.919, 95% CI: 0.885-0.946; both P < 0.001). At the same sensitivity of 95.7%, our models showed an increase in specificity by 5.56% (P = 0.076) and 6.11% (P = 0.035), respectively, as compared to the KS.
CONCLUSION: The models incorporating MRI features (root sign, TIC, margins, internal enhancement, and presence of edema), quantitative ADC value, and patient age showed improved diagnostic performance and might have avoided more unnecessary biopsies in comparison with the KS, although further external validation is required.
引用
- Meng, Zhao, Guo, et al. Improved Differential Diagnosis Based on BI-RADS Descriptors and Apparent Diffusion Coefficient for Breast Lesions: A Multiparametric MRI Analysis as Compared to Kaiser Score. Acad Radiol. 2023. PMID: 37236897. doi:10.1016/j.acra.2023.03.035
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。