文献速递胸部技术与安全DR

基于标签相关Transformer的胸部X线自动诊断及可靠可解释性研究

Label correlation transformer for automated chest X-ray diagnosis with reliable interpretability.
PubMed 文献 · Radiol Med · 2023-05-26

本研究提出一种基于Transformer的深度学习模型,利用其查询结构捕捉图像全局与局部信息及标签间相关性,并引入新损失函数辅助模型发现标签关联;在Chest X-ray 14数据集上平均AUC为0.831,在PadChest数据集上为0.875,优于现有方法;注意力热图显示模型可聚焦于医师标注的真实致病区域。

要点

  • 模型在Chest X-ray 14平均AUC 0.831、PadChest 0.875,优于现有方法。
  • 注意力热图可聚焦医师标注的真实致病区域,提供可靠可解释性。
  • 新损失函数帮助模型发现胸部X线图像中标签间的相关性。

核心结论

  • 所提模型有效提升了胸部X线多标签分类性能及标签相关性的可解释性,为自动化临床诊断提供新证据和方法。

研究设计与样本

  • 提出基于Transformer的深度学习模型用于胸部X线自动诊断,采用独特查询结构捕捉图像全局与局部信息及标签间相关性,并引入新损失函数;在Chest X-ray 14和PadChest数据集上评估,以医师标注的真实致病区域作为可解释性参考。

关键影像表现/征象

  • 注意力热图显示模型可聚焦于相关真实标注致病区域的精确对应区域。

诊断标准与关键数值

  • Chest X-ray 14数据集上平均AUC为0.831。
  • PadChest数据集上平均AUC为0.875。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Computer-aided diagnosis of chest X-ray (CXR) images can help reduce the huge workload of radiologists and avoid the inter-observer variability in large-scale early disease screening. Recently, most state-of-the-art studies employ deep learning techniques to address this problem through multi-label classification. However, existing methods still suffer from low classification accuracy and poor interpretability for each diagnostic task. This study aims to propose a novel transformer-based deep learning model for automated CXR diagnosis with high performance and reliable interpretability. We introduce a novel transformer architecture into this problem and utilize the unique query structure of transformer to capture the global and local information of the images and the correlation between labels. In addition, we propose a new loss function to help the model find correlations between the labels in CXR images. To achieve accurate and reliable interpretability, we generate heatmaps using the proposed transformer model and compare with the true pathogenic regions labeled by the physicians. The proposed model achieves a mean AUC of 0.831 on chest X-ray 14 and 0.875 on PadChest dataset, which outperforms existing state-of-the-art methods. The attention heatmaps show that our model could focus on the exact corresponding areas of related truly labeled pathogenic regions. The proposed model effectively improves the performance of CXR multi-label classification and the interpretability of label correlations, thus providing new evidence and methods for automated clinical diagnosis.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Sun, Qu, Luo, et al. Label correlation transformer for automated chest X-ray diagnosis with reliable interpretability. Radiol Med. 2023. PMID: 37233906. doi:10.1007/s11547-023-01647-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。