基于深度学习的计算机辅助诊断用于超声乳腺病灶分类:一项无乳腺超声专长放射科医师的前瞻性多中心研究
前瞻性多中心研究纳入中国8家二级或农村医院313例BI-RADS 3-5类乳腺病灶(≤2.0 cm),由无乳腺超声专长的放射科医师行超声并赋值BI-RADS,CAD将3类升级为4A、4A降级为3类。应用CAD后准确率86.6% vs 62.6%、特异度82.9% vs 46.0%、PPV 72.7% vs 46.5%均显著提高,敏感度与NPV无显著差异。
要点
- CAD将6.0%(6/100)的BI-RADS 3类升级为4A,其中16.7%(1/6)恶性。
- CAD将79.1%(87/110)的BI-RADS 4A类降级为3类,其中4.6%(4/87)恶性。
- 应用CAD后准确率86.6% vs 62.6%、特异度82.9% vs 46.0%、PPV 72.7% vs 46.5%均显著提高。
核心结论
- CAD显著改善无乳腺超声专长放射科医师的诊断性能,尤其可能减少良性乳腺活检频率。
研究设计与样本
- 前瞻性多中心研究,纳入中国8家二级或农村医院313例患者313个乳腺病灶(102恶性、211良性),以活检或手术切除组织学为参考标准。
诊断标准与关键数值
- CAD将读者判定的BI-RADS 3类升级为4A、4A类降级为3类;应用CAD后准确率86.6% vs 62.6%(p < .001)、特异度82.9% vs 46.0%(p < .001)、PPV 72.7% vs 46.5%(p < .001)、敏感度94.1% vs 97.1%(p = .38)、NPV 96.7% vs 97.0%(p > .99)。
临床应用与阅片要点
- CAD可用于将无乳腺超声专长医师判定的BI-RADS 3类升级为4A、4A类降级为3类,以改善诊断准确率、特异度和PPV并可能减少良性活检。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND. Computer-aided diagnosis (CAD) systems for breast ultrasound interpretation have been primarily evaluated at tertiary and/or urban medical centers by radiologists with breast ultrasound expertise. OBJECTIVE. The purpose of this study was to evaluate the usefulness of deep learning-based CAD software on the diagnostic performance of radiologists without breast ultrasound expertise at secondary or rural hospitals in the differentiation of benign and malignant breast lesions measuring up to 2.0 cm on ultrasound. METHODS. This prospective study included patients scheduled to undergo biopsy or surgical resection at any of eight participating secondary or rural hospitals in China of a breast lesion classified as BI-RADS category 3-5 on prior breast ultrasound from November 2021 to September 2022. Patients underwent an additional investigational breast ultrasound, performed and interpreted by a radiologist without breast ultrasound expertise (hybrid body/breast radiologists, either who lacked breast imaging subspecialty training or for whom the number of breast ultrasounds performed annually accounted for less than 10% of all ultrasounds performed annually by the radiologist), who assigned a BI-RADS category. CAD results were used to upgrade reader-assigned BI-RADS category 3 lesions to category 4A and to downgrade reader-assigned BI-RADS category 4A lesions to category 3. Histologic results of biopsy or resection served as the reference standard. RESULTS. The study included 313 patients (mean age, 47.0 ± 14.0 years) with 313 breast lesions (102 malignant, 211 benign). Of BI-RADS category 3 lesions, 6.0% (6/100) were upgraded by CAD to category 4A, of which 16.7% (1/6) were malignant. Of category 4A lesions, 79.1% (87/110) were downgraded by CAD to category 3, of which 4.6% (4/87) were malignant. Diagnostic performance was significantly better after application of CAD, in comparison with before application of CAD, in terms of accuracy (86.6% vs 62.6%, p < .001), specificity (82.9% vs 46.0%, p < .001), and PPV (72.7% vs 46.5%, p < .001) but not significantly different in terms of sensitivity (94.1% vs 97.1%, p = .38) or NPV (96.7% vs 97.0%, p > .99). CONCLUSION. CAD significantly improved radiologists' diagnostic performance, showing particular potential to reduce the frequency of benign breast biopsies. CLINICAL IMPACT. The findings indicate the ability of CAD to improve patient care in settings with incomplete access to breast imaging expertise.
引用
- He, Chen, Bai, et al. Deep Learning-Based Computer-Aided Diagnosis for Breast Lesion Classification on Ultrasound: A Prospective Multicenter Study of Radiologists Without Breast Ultrasound Expertise. AJR Am J Roentgenol. 2023. PMID: 37222275. doi:10.2214/AJR.23.29328
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。