文献速递心血管CT

超高分辨率冠状动脉造影中时间分辨率的重要性:光子计数探测器CT证据

The Importance of Temporal Resolution for Ultra-High-Resolution Coronary Angiography: Evidence From Photon-Counting Detector CT.
PubMed 文献 · Invest Radiol · 2023-05-22

回顾性纳入30例行超高分辨率冠状动脉CT血管成像的患者,比较单源125毫秒与双源66毫秒重建的时间分辨率对图像质量的影响。66毫秒重建在右冠状动脉、左前降支及回旋支的主观图像质量、支架内腔显示、支架开花伪影及血管和支架锐利度方面均优于125毫秒重建,且主观图像质量不受心率影响。

要点

  • 在光子计数探测器CT超高分辨率模式下,66毫秒重建较125毫秒重建可显著减少运动伪影并改善冠状动脉各支的血管显示。
  • 对于置入冠状动脉支架的患者,66毫秒重建的支架内腔可视化及支架锐利度优于125毫秒重建,支架开花伪影更低。
  • 125毫秒重建的主观图像质量在高心率时显著下降,而66毫秒重建未见此关联。

核心结论

  • 光子计数探测器CT超高分辨率模式下的冠状动脉造影从高时间分辨率中获益显著,表现为运动伪影更少、血管显示及支架内腔可视化更优、支架开花伪影更少、血管和支架锐利度更高。

研究设计与样本

  • 回顾性、经机构审查委员会批准的研究,纳入30例患者(9例女性,平均年龄80±10岁),使用临床双源光子计数探测器CT行超高分辨率冠状动脉CT血管成像。

关键影像表现/征象

  • 66毫秒重建在右冠状动脉、左前降支及回旋支的主观图像质量均显著优于125毫秒重建(所有P<0.01;读者间一致性Krippendorff α=0.84-1.00)。
  • 125毫秒重建的主观图像质量在高心率时显著下降(ρ=0.21,P<0.05),而66毫秒重建未见显著关联(ρ=0.11,P=0.22)。
  • 心率变异性与两种重建(125毫秒:ρ=0.09,P=0.33;66毫秒:ρ=0.13,P=0.17)的图像质量均无关联。

诊断标准与关键数值

  • 图像采集参数:管电压120 kV,准直120×0.2 mm,机架旋转时间0.25秒。
  • 重建参数:层厚0.2 mm,量子迭代重建强度4级;无冠状动脉支架患者使用Bv64卷积核,有支架患者使用Bv72卷积核。
  • 主观图像质量采用5点离散视觉量表评估运动伪影和血管显示或支架内腔可视化。
  • 66毫秒重建的支架开花伪影为46.7%±10%,低于125毫秒重建的52.9%±8.9%(P<0.001)。
  • 66毫秒重建的血管锐利度高于125毫秒重建:左前降支1031±265 ΔHU/mm vs 819±253 ΔHU/mm(P<0.01);右冠状动脉884±352 ΔHU/mm vs 654±377 ΔHU/mm(P<0.001);支架5318±3874 ΔHU/mm vs 4267±3521 ΔHU/mm(P<0.001)。

临床应用与阅片要点

  • 在光子计数探测器CT超高分辨率冠状动脉成像中,采用双源66毫秒重建可改善冠状动脉各支的主观图像质量,尤其对高心率患者。
  • 对置入冠状动脉支架的患者,66毫秒重建可减少支架开花伪影并提高支架内腔可视化及支架锐利度。
  • 信噪比和对比噪声比在66毫秒与125毫秒重建间无显著差异(均P>0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The aim of this study was to assess the effect of temporal resolution on subjective and objective image quality of coronary computed tomography angiography (CCTA) in the ultra-high-resolution (UHR) mode with dual-source photon-counting detector (PCD) CT.

MATERIALS AND METHODS: This retrospective, institutional review board-approved study evaluated 30 patients (9 women; mean age, 80 ± 10 years) undergoing UHR CCTA with a clinical dual-source PCD-CT scanner. Images were acquired with a tube voltage of 120 kV and using a collimation of 120 × 0.2 mm. Gantry rotation time was 0.25 seconds. Each scan was reconstructed using both single-source and dual-source data resulting in an image temporal resolution of 125 milliseconds and 66 milliseconds, respectively. The average heart rate and the heart rate variability were recorded. Images were reconstructed with a slice thickness of 0.2 mm, quantum iterative reconstruction strength level 4, and using the Bv64 and Bv72 kernel for patients without and with coronary stents, respectively. For subjective image quality, 2 experienced readers rated motion artifacts and vessel delineation, or in-stent lumen visualization using 5-point discrete visual scales. For objective image quality, signal-to-noise ratio, contrast-to-noise ratio, stent blooming artifacts, and vessel and stent sharpness were quantified.

RESULTS: Fifteen patients had coronary stents, and 15 patients had no coronary stents. The mean heart rate and heart rate variability during data acquisition were 72 ± 10 beats per minute and 5 ± 6 beats per minute, respectively. Subjective image quality in the right coronary artery, left anterior descending, and circumflex artery was significantly superior in 66 milliseconds reconstructions compared with 125 milliseconds reconstructions for both readers (all P 's < 0.01; interreader agreement, Krippendorff α = 0.84-1.00). Subjective image quality deteriorated significantly at higher heart rates for 125 milliseconds (ρ = 0.21, P < 0.05) but not for 66 milliseconds reconstructions (ρ = 0.11, P = 0.22). No association was found between heart rate variability and image quality for both 125 milliseconds (ρ = 0.09, P = 0.33) and 66 milliseconds reconstructions (ρ = 0.13, P = 0.17), respectively. Signal-to-noise ratio and contrast-to-noise ratio were similar between 66 milliseconds and 125 milliseconds reconstructions (both P 's > 0.05), respectively. Stent blooming artifacts were significantly lower on 66 milliseconds than on 125 milliseconds reconstructions (46.7% ± 10% vs 52.9% ± 8.9%, P < 0.001). Higher sharpness was found in 66 milliseconds than in 125 milliseconds reconstructions both in native coronary arteries (left anterior descending artery: 1031 ± 265 ∆HU/mm vs 819 ± 253 ∆HU/mm, P < 0.01; right coronary artery: 884 ± 352 ∆HU/mm vs 654 ± 377 ∆HU/mm, P < 0.001) and stents (5318 ± 3874 ∆HU/mm vs 4267 ± 3521 ∆HU/mm, P < 0.001).

CONCLUSIONS: Coronary angiography with PCD-CT in the UHR mode profits considerably from a high temporal resolution, resulting in less motion artifacts, superior vessel delineation and in-stent lumen visualization, less stent blooming artifacts, and superior vessel and stent sharpness.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Mergen, Sartoretti, Cundari, et al. The Importance of Temporal Resolution for Ultra-High-Resolution Coronary Angiography: Evidence From Photon-Counting Detector CT. Invest Radiol. 2023. PMID: 37222522. doi:10.1097/RLI.0000000000000987

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。