采用容积表观扩散系数直方图分析壶腹周围癌的胰胆管型与肠型
本研究回顾性纳入69例经组织病理学证实的壶腹周围腺癌患者(胰胆管型54例、肠型15例),基于b值1000 mm²/s的扩散加权成像计算容积ADC直方图参数。胰胆管型组ADC各参数均低于肠型组,但仅峰度(P=0.003)及第5(P=0.032)、第10(P=0.043)、第25(P=0.037)百分位数差异有统计学意义;峰度AUC最高(0.752,截断值-0.235,敏感度61.1%,特异度80.0%)。结论认为容积ADC直方图分析可在术前无创区分两种亚型。
要点
- 胰胆管型壶腹周围腺癌的ADC直方图各参数均低于肠型。
- 峰度、第5、第10、第25百分位数ADC值在两组间差异有统计学意义。
- 峰度鉴别两型的AUC为0.752,截断值-0.235,敏感度61.1%,特异度80.0%。
核心结论
- b值1000 mm²/s的容积ADC直方图分析可在术前无创区分胰胆管型与肠型壶腹周围腺癌。
研究设计与样本
- 回顾性研究,纳入69例经组织病理学证实的壶腹周围腺癌患者(胰胆管型54例、肠型15例),采用b值1000 mm²/s的扩散加权成像,由两名放射科医师独立计算ADC直方图参数,并以组内相关系数评价观察者间一致性。
诊断标准与关键数值
- 胰胆管型组ADC各参数均低于肠型组,而方差、偏度、峰度高于肠型组;峰度(P=0.003)、第5百分位数(P=0.032)、第10百分位数(P=0.043)、第25百分位数(P=0.037)的组间差异有统计学意义;峰度AUC=0.752,截断值-0.235,敏感度61.1%,特异度80.0%。
临床应用与阅片要点
- 作者认为容积ADC直方图分析可在术前无创区分壶腹周围腺癌的胰胆管型与肠型。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Magnetic resonance imaging plays an important role in the evaluation of patients with known or suspected periampullary masses. The utilization of volumetric apparent diffusion coefficient (ADC) histogram evaluation for the entire lesion eradicates the potential for subjectivity in the region of interest placement, thus guaranteeing the accuracy of computation and repeatability.
PURPOSE: To investigate the value of volumetric ADC histogram analysis in the differentiation of intestinal-type (IPAC) and pancreatobiliary-type periampullary adenocarcinomas (PPAC).
MATERIALS AND METHODS: This retrospective study included 69 patients with histopathologically confirmed periampullary adenocarcinoma (54 PPAC and 15 IPAC). Diffusion-weighted imaging was obtained at b values of 1000 mm²/s. The histogram parameters of ADC values, comprising the mean, minimum, maximum, 5th, 10th, 25th, 50th, 75th, 90th, and 95th percentiles, as well as skewness, kurtosis, and variance, were calculated independently by two radiologists. Using the interclass correlation coefficient, the interobserver agreement was evaluated.
RESULTS: The ADC parameters for the PPAC group were all lower than those of the IPAC group. The PPAC group had higher variance, skewness, and kurtosis than the IPAC group. However, the difference between the kurtosis (P = .003), the 5th (P = .032), 10th (P = .043), and 25th (P = .037) percentiles of ADC values was statistically significant. The area under the curve (AUC) of the kurtosis was the highest (AUC=0.752; cut-off value=-0.235; sensitivity=61.1%; specificity=80.0%).
CONCLUSION: Volumetric ADC histogram analysis with b values of 1000 mm²/s can discriminate subtypes noninvasively before surgery.
引用
- Nalbant, Oner, Akinci, et al. Analysis of Pancreatobiliary and Intestinal Type Periampullary Carcinomas Using Volumetric Apparent Diffusion Coefficient Histograms. Acad Radiol. 2023. PMID: 37211479. doi:10.1016/j.acra.2023.04.031
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。