胰腺双能量CT:虚拟平扫与真实平扫图像在胰腺病灶检出中的比较
回顾性纳入106例胰腺肿块患者,比较双能量CT晚期动脉期和门静脉期生成的虚拟平扫与真实平扫的图像质量及病灶检出准确率。TNC与aVNC间78.38%的测量可重复,TNC与pVNC间71.0%可重复;三期中106例共108个病灶,TNC与VNC检出准确率无显著差异(p=0.587–0.957);所有VNC图像质量评分≥3分,省略平扫期可降低CTDIvol和SSDE约34%。结论认为VNC图像具有诊断级图像质量并能准确检出胰腺病灶,是平扫期的有前景替代方案并可大幅降低辐射暴露。
要点
- TNC与aVNC测量可重复率78.38%(765/976),TNC与pVNC为71.0%(693/976)。
- 三期中106例共108个胰腺病灶,TNC与VNC检出准确率无显著差异(p=0.587–0.957)。
- 省略平扫期后CTDIvol和SSDE降低约34%。
核心结论
- DECT生成的VNC图像具有诊断级图像质量并能准确检出胰腺病灶,是平扫期的有前景替代方案,可在临床常规中大幅降低辐射暴露。
研究设计与样本
- 回顾性纳入106例胰腺肿块患者,行对比增强DECT检查,由晚期动脉期和门静脉期生成腹部VNC图像(aVNC和pVNC),比较TNC与aVNC/pVNC的腹部器官衰减差异和可重复性,并由两名放射科医师用五分法评估图像质量、独立比较胰腺病灶检出准确率。
诊断标准与关键数值
- TNC与aVNC间78.38%(765/976)的衰减测量对可重复,TNC与pVNC间71.0%(693/976)可重复;三期中106例共108个胰腺病灶,TNC与VNC检出准确率无显著差异(p=0.587–0.957);所有VNC图像质量均评为可诊断(评分≥3分)。
临床应用与阅片要点
- 原文结论认为VNC图像是平扫期的有前景替代方案,可大幅降低辐射暴露;省略平扫期后CTDIvol和SSDE降低约34%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the image quality and diagnostic performance for pancreatic lesion between true non-contrast (TNC) and virtual non-contrast (VNC) images obtained from the dual-energy computed tomography (DECT).
METHODS: One hundred six patients with pancreatic mass underwent contrast-enhanced DECT examinations were retrospectively included in this study. VNC images of the abdomen were generated from late arterial (aVNC) and portal (pVNC) phases. For quantitative analysis, the attenuation differences and reproducibility of abdominal organs were compared between TNC and aVNC/pVNC measurements. Qualitatively image quality was assessed by two radiologists using a five-point scale, and they independently compared the detection accuracy of pancreatic lesions between TNC and aVNC/pVNC images. The volume CT dose index (CTDIvol) and size-specific dose estimates (SSDE) were recorded to evaluate the potential dose reduction when using VNC reconstruction to replace the unenhanced phase.
RESULTS: A total of 78.38% (765/976) of the attenuation measurement pairs were reproducible between TNC and aVNC images, and 71.0% (693/976) between TNC and pVNC images. In triphasic examinations, a total of 108 pancreatic lesions were found in 106 patients, and no significant difference in detection accuracy was found between TNC and VNC images (p = 0.587-0.957). Qualitatively, image quality was rated diagnostic (score ≥ 3) in all the VNC images. Calculated CTDIvol and SSDE reduction of about 34% could be achieved by omitting the non-contrast phase.
CONCLUSION: VNC images of DECT provide diagnostic image quality and accurate pancreatic lesions detection, which are a promising alternative to unenhanced phase with a substantial reduction of radiation exposure in clinical routine.
引用
- Liang, Du, Yan, et al. Dual-energy CT of the pancreas: comparison between virtual non-contrast images and true non-contrast images in the detection of pancreatic lesion. Abdom Radiol (NY). 2023. PMID: 37210407. doi:10.1007/s00261-023-03914-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。