谐波运动成像中幅度调制频率对包涵体表征的影响

The impact of amplitude modulation frequency in harmonic motion imaging on inclusion characterization.
PubMed 文献 · Ultrasound Med Biol · 2023-05-16

本研究利用嵌入不同大小和硬度包涵体的组织模拟体模,在25至250 Hz幅度调制频率范围内进行谐波运动成像,发现对比度和对比噪声比达到最大的频率取决于包涵体的大小和硬度,较小包涵体在较高频率处达峰,相同大小但硬度较高者优化频率也较高;对含2.7 cm乳腺肿瘤的离体人标本成像显示最高对比度和对比噪声比出现在50 Hz。

要点

  • 谐波运动成像中幅度调制频率影响包涵体对比度和对比噪声比,优化频率取决于包涵体大小和硬度。
  • 较小包涵体的对比度和对比噪声比峰值出现在较高幅度调制频率。
  • 相同大小但硬度较高的包涵体,其优化幅度调制频率也较高。

核心结论

  • 谐波运动成像的幅度调制频率可在不同应用中优化,尤其用于临床改善不同几何和力学特性肿瘤的检测与表征。

研究设计与样本

  • 研究使用嵌入不同大小和硬度包涵体的组织模拟体模,在25至250 Hz幅度调制频率范围内以25 Hz步长成像,并成像含2.7 cm乳腺肿瘤的离体人标本。

诊断标准与关键数值

  • 对比度和对比噪声比达到最大的幅度调制频率取决于包涵体的大小和硬度。
  • 较小包涵体的对比度和对比噪声比峰值出现在较高频率。
  • 相同大小但硬度不同的包涵体,优化幅度调制频率随硬度增加而升高。
  • 对比度峰值频率与对比噪声比最大频率之间存在偏移。
  • 含2.7 cm乳腺肿瘤的离体人标本在50 Hz幅度调制频率处获得最高对比度和对比噪声比。

临床应用与阅片要点

  • 谐波运动成像的幅度调制频率可根据目标的大小和力学特性进行调整,以改善检测和表征。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Ultrasound elasticity imaging techniques aim to provide a non-invasive characterization of tissue mechanical properties to detect pathological changes and monitor disease progression. Harmonic motion imaging (HMI) is an ultrasound-based elasticity imaging technique that utilizes an oscillatory acoustic radiation force to induce localized displacements and estimate relative tissue stiffness. Previous studies have applied a low amplitude modulation (AM) frequency of 25 or 50 Hz in HMI to assess the mechanical properties of different tissue types. In this study, we investigate the dependence of AM frequency in HMI and whether the frequency can be adjusted based on the size and mechanical properties of the underlying medium for enhanced image contrast and inclusion detection.

METHODS: A tissue-mimicking phantom with embedded inclusions at different sizes and stiffnesses was imaged within a range of AM frequencies from 25 to 250 Hz at 25-Hz step size.

DISCUSSION: The AM frequency at which the maximum contrast and CNR are achieved depends on the size and stiffness of the inclusions. A general trend shows that contrast and CNR peak at higher frequencies for smaller inclusions. In addition, for some inclusions with the same size but different stiffnesses, the optimized AM frequency increases with the stiffness of the inclusion. Nevertheless, there is a shift between the frequencies at which the contrast peaks and those with maximum CNR. Finally, in agreement with the phantom findings, imaging an ex-vivo human specimen with a 2.7-cm breast tumor at a range of AM frequencies showed that the highest contrast and CNR are achieved at the AM frequency of 50 Hz.

CONCLUSION: These findings indicate that the AM frequency can be optimized in different applications of HMI, especially in the clinic, for improved detection and characterization of tumors with different geometries and mechanical properties.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。