左心房旋转血流减低与栓塞性脑梗死独立相关
本研究纳入134例患者(44例有缺血性卒中史,90例无卒中史但CHA2DS2VASc评分≥1),用心脏磁共振四维血流评估左心房血流参数,脑磁共振检测梗死。校正房颤等因素后,左心房涡量降低与现患大非皮质或皮质梗死独立相关(OR 2.06,95%CI 1.08-3.92每标准差,P=0.027),而左心房血流峰值速度无显著关联(P=0.21)。
要点
- 左心房涡量每降低1个标准差,大非皮质或皮质梗死风险增加,OR 2.06(95%CI 1.08-3.92),P=0.027。
- 左心房血流峰值速度与大非皮质或皮质梗死无显著关联(P=0.21)。
- 任何左心房参数与腔隙性梗死均无显著关联(所有P>0.05)。
核心结论
- 左心房血流涡量降低与栓塞性脑梗死显著且独立相关,该关联独立于房颤存在。
研究设计与样本
- 研究纳入134例患者,其中44例有缺血性卒中史、90例无卒中史但CHA2DS2VASc评分≥1;采用心脏磁共振评估心脏功能及左心房四维血流参数(包括速度和涡量),并以脑磁共振检测大非皮质或皮质梗死(可能为栓塞性)及非栓塞性腔隙性梗死。
诊断标准与关键数值
- 左心房涡量降低与大非皮质或皮质梗死相关,校正房颤、房颤史、CHA2DS2VASc评分、左心房排空分数、左心房最大容积指数、左心室射血分数及左心室质量指数后OR 2.06(95%CI 1.08-3.92每标准差),P=0.027。
- 左心房血流峰值速度与大非皮质或皮质梗死无显著关联(P=0.21)。
- 所有左心房参数与腔隙性梗死均无显著关联(所有P>0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Up to 25% of embolic strokes occur in individuals without atrial fibrillation (AF) or other identifiable mechanisms.
OBJECTIVES: This study aims to assess whether left atrial (LA) blood flow characteristics are associated with embolic brain infarcts, independently of AF.
METHODS: The authors recruited 134 patients: 44 with a history of ischemic stroke and 90 with no history of stroke but CHA2DS2VASc score ≥1. Cardiac magnetic resonance (CMR) evaluated cardiac function and LA 4-dimensional flow parameters, including velocity and vorticity (a measure of rotational flow), and brain magnetic resonance imaging (MRI) was performed to detect large noncortical or cortical infarcts (LNCCIs) (likely embolic), or nonembolic lacunar infarcts.
RESULTS: Patients (41% female; age 70 ± 9 years) had moderate stroke risk (median CHA2DS2VASc = 3, Q1-Q3: 2-4). Sixty-eight (51%) had diagnosed AF, of whom 58 (43%) were in AF during CMR. Thirty-nine (29%) had ≥1 LNCCI, 20 (15%) had ≥1 lacunar infarct without LNCCI, and 75 (56%) had no infarct. Lower LA vorticity was significantly associated with prevalent LNCCIs after adjustment for AF during CMR, history of AF, CHA2DS2VASc score, LA emptying fraction, LA indexed maximum volume, left ventricular ejection fraction, and indexed left ventricular mass (OR: 2.06 [95% CI: 1.08-3.92 per SD]; P = 0.027). By contrast, LA flow peak velocity was not significantly associated with LNCCIs (P = 0.21). No LA parameter was associated with lacunar infarcts (all P > 0.05).
CONCLUSIONS: Reduced LA flow vorticity is significantly and independently associated with embolic brain infarcts. Imaging LA flow characteristics may aid identification of individuals who would benefit from anticoagulation for embolic stroke prevention, regardless of heart rhythm.
引用
- Spartera, Stracquadanio, Pessoa-Amorim, et al. Reduced Left Atrial Rotational Flow Is Independently Associated With Embolic Brain Infarcts. JACC Cardiovasc Imaging. 2023. PMID: 37204381. doi:10.1016/j.jcmg.2023.03.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。