文献速递神经儿科影像MR

利用磁共振成像测量表面健康胎儿的蛛网膜下腔

Subarachnoid Space Measurements in Apparently Healthy Fetuses Using MR Imaging.
PubMed 文献 · AJNR Am J Neuroradiol · 2023-05-18

本研究基于2012至2020年一家大型三级医疗中心随机选取的表面健康胎儿脑部MR图像进行回顾性横断面评估,在10个参考点测量蛛网膜下腔大小,纳入孕28至37周的214例胎儿。研究描述了各孕周各测量值的第3、15、50、85、97百分位,观察者间与观察者内一致性良好。

要点

  • 孕28至37周表面健康胎儿的MR蛛网膜下腔测量值按孕周给出百分位参考范围。
  • 10个参考点中除1个参数外,观察者间与观察者内ICC均大于0.75。
  • MR测量蛛网膜下腔可重复性高,可能源于高分辨率及遵循真实放射学平面。

核心结论

  • 特定孕周的MR来源蛛网膜下腔测量值可重复性好,正常值可为评估脑发育及临床决策提供参考信息。

研究设计与样本

  • 回顾性横断面研究,随机选取2012至2020年一家大型三级医疗中心表面健康胎儿的脑部MR图像,纳入孕28至37周、排除图像质量低、多胎及颅内病变者,共214例胎儿,母亲平均年龄31.2岁(SD 5.4)。

诊断标准与关键数值

  • 在轴位和冠状面10个参考点测量蛛网膜下腔大小,按每个孕周描述第3、15、50、85、97百分位;观察者间与观察者内一致性除1个参数外ICC均大于0.75。

临床应用与阅片要点

  • 作者认为MR来源的正常值可为评估脑发育提供参考信息,并作为临床医生与家长决策过程中的重要工具。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: The fetal subarachnoid space size serves as an indicator of normal brain development. The subarachnoid space is commonly measured by an ultrasound examination. Introduction of MR imaging for fetal brain evaluation enables standardization of MR imaging-driven subarachnoid space parameters for a more accurate evaluation. This study aimed to determine the normal range of MR imaging-derived subarachnoid space size in fetuses according to gestational age.

MATERIALS AND METHODS: A cross-sectional study based on a retrospective assessment of randomly selected brain MR images of apparently healthy fetuses performed between 2012 and 2020 at a large tertiary medical center was performed. Demographic data were collected from the mothers' medical records. Subarachnoid space size was measured at 10 reference points using the axial and coronal planes. Only MR imaging scans obtained between weeks 28 and 37 of pregnancy were included. Scans with low-quality images, multiple pregnancy, and cases with intracranial pathologic findings were excluded.

RESULTS: Overall, 214 apparently healthy fetuses were included (mean maternal age, 31.2 [SD, 5.4] years). Good interobserver and intraobserver agreement was observed (intraclass correlation coefficient > 0.75 for all except 1 parameter). For each gestational week, the 3rd, 15th, 50th, 85th, and 97th percentiles of each subarachnoid space measurement were described.

CONCLUSIONS: MR imaging-derived subarachnoid space values at a specific gestational age provide reproducible measurements, probably due to the high resolution of MR imaging and adherence to the true radiologic planes. Normal values for brain MR imaging could provide valuable reference information for assessing brain development, thus being an important tool in the decision-making process of both clinicians and parents.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Wandel, Weissbach, Katorza, et al. Subarachnoid Space Measurements in Apparently Healthy Fetuses Using MR Imaging. AJNR Am J Neuroradiol. 2023. PMID: 37202119. doi:10.3174/ajnr.A7864

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。