儿童动脉瘤样骨囊肿活检新方法:心内膜心肌活检钳的应用
回顾性研究纳入18例疑似动脉瘤样骨囊肿的儿童患者共23次经皮活检,评估使用心内膜心肌活检钳获取组织以提高诊断率。结果显示,使用活检钳的活检诊断率为100.0%,而标准方法为40.0%(p=0.008),无并发症发生。
要点
- 儿童疑似动脉瘤样骨囊肿经皮活检时,心内膜心肌活检钳诊断率100.0%,标准方法40.0%(p=0.008)。
- 总体病理确诊率为56.5%(13/23次活检),确诊者中1例为单房性骨囊肿,其余均为动脉瘤样骨囊肿。
- 活检钳使用7例(30.4%),其中2例为唯一使用的器械,无并发症发生。
核心结论
- 心内膜心肌活检钳为疑似动脉瘤样骨囊肿的活检提供了一种额外的新技术,可能提高诊断率。
研究设计与样本
- 回顾性研究,为期17年,纳入18例年龄<18岁的患者(女性11例),共23次经皮活检;活检器械选择和组织获取量由儿科介入放射科医生决定;采用Fisher精确检验比较标准活检与活检钳活检的诊断率。
诊断标准与关键数值
- 诊断性活检定义为组织学确诊;不确定的发现或提示但未确诊动脉瘤样骨囊肿的发现视为非诊断性,即使影像和临床特征典型;标准方法诊断率40.0% vs 活检钳100.0%(p=0.008)。
临床应用与阅片要点
- 对于影像提示动脉瘤样骨囊肿的儿童患者,经皮活检时可考虑使用心内膜心肌活检钳以获取更大组织碎片,从而提高诊断率。
局限性
- 本研究为回顾性研究。
- 活检器械选择和组织获取量由儿科介入放射科医生决定。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The thin and friable septations composing aneurysmal bone cysts (ABC) may be challenging to target for percutaneous biopsy. The purpose of this study was to describe and evaluate a novel method of ABC biopsy using endomyocardial biopsy forceps as an attempt to capture larger fragments of tissue for diagnosis.
METHODS AND MATERIALS: This was a retrospective study performed over a 17-year period. Patients <18 years old who underwent percutaneous biopsy for a presumed ABC, based on pre-procedure imaging, were included. Medical records were reviewed to identify age, sex, lesion location, biopsy procedure details, complications, and pathology results. A diagnostic biopsy was defined as conclusive histologic confirmation. Inconclusive findings or findings suggestive of but not diagnostic of an ABC were treated as non-diagnostic, even if imaging and clinical findings were characteristic. Biopsy device selection and quantity of tissue obtained was at the discretion of the pediatric interventional radiologist. Fisher's exact test was used to compare the diagnostic yield of standard biopsies to those employing biopsy forceps.
RESULTS: Twenty-three biopsies were performed in 18 patients (11 female) with a median age of 14.7 years (IQR 10.6-15.6). Lesions were located in the extremities (7, 30.4%), chest (6, 26.1%), pelvis (5, 21.7%), spine (4, 17.4%), and mandible (1, 4.3%). Specimens were obtained using a 13- or 15-gauge bone coring needle (11, 47.8%); 14-, 16-, or 18-gauge soft tissue needle (6, 26.1%); or a combination of bone and soft tissue (4, 17.4%) needles. Endomyocardial biopsy forceps were utilized in 7 cases (30.4%), 2 in which it was the only device used. Overall, a conclusive pathologic diagnosis was made in 13/23 (56.5%) biopsies. Of the diagnostic biopsies, 1 was a unicameral bone cyst and all others were ABCs. No malignancy was identified. Compared to the standard approach, the use of forceps was more likely to result in a diagnostic biopsy (40.0% vs 100.0%, p = 0.008). There were no complications.
CONCLUSIONS: Endomyocardial biopsy forceps offer an additional, novel technique to biopsy presumed ABCs and may improve diagnostic yield.
引用
- Gaballah, Worede, Alexander, et al. Novel method to biopsy aneurysmal bone cysts in children. Skeletal Radiol. 2023. PMID: 37191930. doi:10.1007/s00256-023-04360-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。