文献速递乳腺乳腺X线

基于人工智能的计算机辅助诊断对数字乳腺X线摄影筛查结局的影响:一项匹配队列研究

Effect of artificial intelligence-based computer-aided diagnosis on the screening outcomes of digital mammography: a matched cohort study.
PubMed 文献 · Eur Radiol · 2023-05-16

该回顾性匹配队列研究纳入3158例无症状韩国女性,比较单读片模式下数字乳腺X线摄影(DM)有无AI-CAD支持的筛查表现。结果显示,AI-CAD支持组特异度更高(96% vs 91.6%)、异常解读率更低(4.9% vs 9.2%),而癌症检出率、敏感度和活检阳性预测值无显著差异。

要点

  • AI-CAD支持单读片DM筛查时,放射科医师特异度从91.6%提高至96%,异常解读率从9.2%降至4.9%。
  • AI-CAD支持与否,癌症检出率(8.9 vs 8.9/1000次检查)、敏感度(87.5% vs 77.8%)和活检阳性预测值(35.0% vs 35.0%)均无显著差异。
  • AI-CAD作为单读片DM筛查的辅助工具,可在不降低敏感度的情况下提高特异度,可能减少假阳性和召回率。

核心结论

  • AI-CAD作为单读片DM乳腺癌筛查的辅助工具,可提高放射科医师的特异度而不降低敏感度。

研究设计与样本

  • 回顾性数据库检索匹配队列研究,纳入3158例无症状韩国女性,在三级转诊医院单读片模式下,比较2019年1月至12月无AI-CAD支持的筛查DM与2020年2月至7月有AI-CAD辅助图像解读的筛查DM;采用倾向性评分按年龄、乳腺密度、读片医师经验水平和筛查轮次1:1匹配。

诊断标准与关键数值

  • AI-CAD支持组 vs 无AI-CAD支持组:特异度96%(1500/1563)vs 91.6%(1430/1561),p < 0.001;异常解读率4.9%(77/1579)vs 9.2%(145/1579),p < 0.001;癌症检出率8.9 vs 8.9/1000次检查,p = 0.999;敏感度87.5% vs 77.8%,p = 0.999;活检阳性预测值35.0% vs 35.0%,p = 0.999。

临床应用与阅片要点

  • 在单读片DM乳腺癌筛查中,AI-CAD可作为支持工具辅助放射科医师决策,提高特异度并降低异常解读率,且不降低敏感度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate whether artificial intelligence-based computer-aided diagnosis (AI-CAD) can improve radiologists' performance when used to support radiologists' interpretation of digital mammography (DM) in breast cancer screening.

METHODS: A retrospective database search identified 3158 asymptomatic Korean women who consecutively underwent screening DM between January and December 2019 without AI-CAD support, and screening DM between February and July 2020 with image interpretation aided by AI-CAD in a tertiary referral hospital using single reading. Propensity score matching was used to match the DM with AI-CAD group in a 1:1 ratio with the DM without AI-CAD group according to age, breast density, experience level of the interpreting radiologist, and screening round. Performance measures were compared with the McNemar test and generalized estimating equations.

RESULTS: A total of 1579 women who underwent DM with AI-CAD were matched with 1579 women who underwent DM without AI-CAD. Radiologists showed higher specificity (96% [1500 of 1563] vs 91.6% [1430 of 1561]; p < 0.001) and lower abnormal interpretation rates (AIR) (4.9% [77 of 1579] vs 9.2% [145 of 1579]; p < 0.001) with AI-CAD than without. There was no significant difference in the cancer detection rate (CDR) (AI-CAD vs no AI-CAD, 8.9 vs 8.9 per 1000 examinations; p = 0.999), sensitivity (87.5% vs 77.8%; p = 0.999), and positive predictive value for biopsy (PPV3) (35.0% vs 35.0%; p = 0.999) according to AI-CAD support.

CONCLUSIONS: AI-CAD increases the specificity for radiologists without decreasing sensitivity as a supportive tool in the single reading of DM for breast cancer screening.

CLINICAL RELEVANCE STATEMENT: This study shows that AI-CAD could improve the specificity of radiologists' DM interpretation in the single reading system without decreasing sensitivity, suggesting that it can benefit patients by reducing false positive and recall rates.

KEY POINTS: • In this retrospective-matched cohort study (DM without AI-CAD vs DM with AI-CAD), radiologists showed higher specificity and lower AIR when AI-CAD was used to support decision-making in DM screening. • CDR, sensitivity, and PPV for biopsy did not differ with and without AI-CAD support.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Kim, Choi, Kim, et al. Effect of artificial intelligence-based computer-aided diagnosis on the screening outcomes of digital mammography: a matched cohort study. Eur Radiol. 2023. PMID: 37188881. doi:10.1007/s00330-023-09692-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。