文献速递妇产影像US

基于结局的五种胎儿生长速度模型比较分析以定义生长缓慢

Outcome-based comparative analysis of five fetal growth velocity models to define slow growth.
PubMed 文献 · Ultrasound Obstet Gynecol · 2023-11-06

该回顾性研究纳入164718例妊娠、480592次晚孕期超声,比较五种临床在用生长缓慢定义模型识别死产风险的效果;仅基于测量间隔的POWR模型能识别出非小于胎龄儿但生长缓慢且死产风险增加的胎儿(相对风险1.58,95%CI 1.04-2.39)。

要点

  • 五种生长缓慢定义模型的检出率差异很大(固定速度20g/天12.7%,固定百分位下降>50为0.7%,固定百分位下降>30为4.6%,第三百分位生长轨迹19.8%,POWR 10.1%)。
  • 仅POWR模型识别出额外非小于胎龄儿生长缓慢妊娠(11237/16671,67.4%),其死产相对风险1.58(95%CI 1.04-2.39)。
  • 末次超声小于胎龄儿对出生小于胎龄儿的阳性预测值为72.8%(9359/12858)。

核心结论

  • 五种临床用生长缓慢定义模型的比较分析显示,仅测量间隔特异性的POWR模型能识别出非小于胎龄儿但生长缓慢且死产风险增加的胎儿。

研究设计与样本

  • 回顾性分析常规收集且匿名化的数据集,纳入至少两次晚孕期超声估测胎儿体重(EFW)的妊娠。
  • 研究队列共164718例妊娠、480592次晚孕期超声(平均2.9±0.9次)。
  • 每例妊娠最后两次超声平均孕周分别为33+5周和37+1周。
  • 小于胎龄儿定义为EFW小于第10百分位(自定义百分位);生长缓慢按五种已发表临床模型定义。

诊断标准与关键数值

  • 小于胎龄儿定义为EFW<第10百分位(自定义百分位)。
  • 生长缓慢模型1:固定速度限值20克/天(FVL20)。
  • 生长缓慢模型2:固定百分位下降>50,不考虑超声测量间隔(FCD50)。
  • 生长缓慢模型3:固定百分位下降>30,不考虑超声测量间隔(FCD30)。
  • 生长缓慢模型4:生长轨迹慢于第三百分位(自定义生长百分位限值,GCL3);模型5:第二次超声EFW低于预测最佳体重范围(POWR),基于部分ROC曲线得出的、特定于测量间隔的截断值。

临床应用与阅片要点

  • 末次超声EFW小于胎龄儿的比例为7.8%(12858例),其中9359例出生时也为小于胎龄儿,阳性预测值72.8%。
  • 各模型定义生长缓慢的比例:FVL20为12.7%,FCD50为0.7%,FCD30为4.6%,GCL3为19.8%,POWR为10.1%。
  • 仅POWR模型识别出额外的非小于胎龄儿生长缓慢妊娠(11237/16671,67.4%),其死产风险显著(相对风险1.58,95%CI 1.04-2.39)。
  • 这些非小于胎龄儿且发生死产的病例末次超声EFW百分位中位数为52.6,出生体重百分位中位数为27.3。
  • 亚组分析发现固定速度模型假设整个孕期线性生长存在方法学问题,基于百分位的方法因极端百分位非参数分布不反映实际体重增长差异而存在问题。

局限性

  • 固定速度模型假设整个孕期线性生长,存在方法学问题。
  • 基于百分位的方法因极端百分位非参数分布不反映实际体重增长差异而存在问题。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Fetal growth surveillance includes assessment of size as well as rate of growth, and various definitions for slow growth have been adopted into clinical use. The aim of this study was to evaluate the effectiveness of different models to identify stillbirth risk, in addition to risk represented by the fetus being small-for-gestational age (SGA).

METHODS: This was a retrospective analysis of a routinely collected and anonymized dataset of pregnancies that had two or more third-trimester ultrasound measurements of estimated fetal weight (EFW). SGA was defined as EFW < 10th customized centile, and slow growth was defined according to five published models in clinical use: (1) a fixed velocity limit of 20 g per day (FVL20 ); (2) a fixed > 50 centile drop, regardless of scan-measurement interval (FCD50 ); (3) a fixed > 30 centile drop, regardless of scan interval (FCD30 ); (4) growth trajectory slower than the third customized growth-centile limit (GCL3 ); and (5) EFW at second scan below the projected optimal weight range (POWR), based on partial receiver-operating-characteristics-curve-derived cut-offs specific to the scan interval.

RESULTS: The study cohort consisted of 164 718 pregnancies with 480 592 third-trimester ultrasound scans (mean ± SD, 2.9 ± 0.9). The last two scans in each pregnancy were performed at an average gestational age of 33 + 5 and 37 + 1 weeks. At the last scan, 12 858 (7.8%) EFWs were SGA, and of these, 9359 were also SGA at birth (positive predictive value, 72.8%). The rate at which slow growth was defined varied considerably (FVL20 , 12.7%; FCD50 , 0.7%; FCD30 , 4.6%; GCL3 , 19.8%; POWR, 10.1%), and there was varying overlap between cases identified as having slow growth and those identified as SGA at the last scan. Only the POWR method identified additional non-SGA pregnancies with slow growth (11 237/16 671 (67.4%)) that had significant stillbirth risk (relative risk, 1.58 (95% CI, 1.04-2.39)). These non-SGA cases resulting in stillbirth had a median EFW centile of 52.6 at the last scan and a median weight centile of 27.3 at birth. Subgroup analysis identified methodological problems with the fixed-velocity model because it assumes linear growth throughout gestation, and with the centile-based methods because the non-parametric distribution of centiles at the extremes does not reflect actual difference in weight gain.

CONCLUSION: Comparative analysis of five clinically used methods to define slow fetal growth has shown that only the measurement-interval-specific POWR model can identify non-SGA fetuses with slow growth that are at increased risk of stillbirth. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Gardosi, Hugh. Outcome-based comparative analysis of five fetal growth velocity models to define slow growth. Ultrasound Obstet Gynecol. 2023. PMID: 37191400. doi:10.1002/uog.26248

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。