文献速递妇产影像泌尿生殖MR

子宫内膜样腺癌:多参数MRI联合肿瘤标志物HE4评估肿瘤分级与淋巴血管间隙浸润

Endometrioid adenocarcinoma: combined multiparametric MRI and tumour marker HE4 to evaluate tumour grade and lymphovascular space invasion.
PubMed 文献 · Clin Radiol · 2023-04-29

研究纳入60例子宫内膜样腺癌患者,术前行盆腔MRI及血清HE4检测,评估半定量DCE-MRI与定量DWI参数联合HE4预测病理分级和淋巴血管间隙浸润的价值。多参数MRI联合HE4诊断G3的AUC为0.929,诊断LVSI阳性的AUC为0.814。结论认为联合预测效能优于任一单一因素。

要点

  • G3肿瘤ADC值低于G1/G2,PEI、MSI及HE4水平高于低级别肿瘤(p<0.05)。
  • 多参数MRI联合HE4诊断G3的AUC为0.929。
  • 多参数MRI联合HE4诊断LVSI阳性的AUC为0.814。

核心结论

  • 半定量DCE-MRI、ADC值及血清HE4水平可用于预测子宫内膜样腺癌的肿瘤分级和淋巴血管间隙浸润。
  • 多参数MRI联合血清HE4的预测效能优于任一单一因素。

研究设计与样本

  • 研究纳入2018年10月至2021年12月间60例子宫内膜样腺癌女性患者,平均年龄55岁(范围32-77岁),术前接受盆腔MRI检查和HE4水平测量。
  • 在肿瘤组织上手动勾画感兴趣区,测量正性增强积分(PEI)、达峰时间、最大上升斜率(MSI)和最大下降斜率。
  • 采用受试者工作特征曲线计算单一参数及联合因素的诊断效能。

关键影像表现/征象

  • 高级别肿瘤(G3)的表观扩散系数(ADC)低于低级别肿瘤(G1/G2)。
  • 高级别肿瘤的PEI、MSI及HE4水平高于低级别肿瘤(p<0.05)。
  • 伴有淋巴血管间隙浸润的子宫内膜样腺癌ADC值显著低于不伴淋巴血管间隙浸润者。
  • 伴有淋巴血管间隙浸润的肿瘤PEI和HE4水平高于不伴淋巴血管间隙浸润者(p<0.05)。

诊断标准与关键数值

  • 多参数MRI联合HE4诊断G3的AUC为0.929。
  • 多参数MRI联合HE4诊断淋巴血管间隙浸润阳性的AUC为0.814。

临床应用与阅片要点

  • 半定量DCE-MRI参数PEI、MSI、ADC值及血清HE4水平可用于预测子宫内膜样腺癌的肿瘤分级和淋巴血管间隙浸润。
  • 多参数MRI联合血清HE4的预测效能优于任一单一因素。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To assess the value of semi-quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and quantitative diffusion-weighted imaging parameters combined with human epididymis protein 4 (HE4) in predicting the pathological grade and lymphovascular space invasion (LVSI) of endometrioid adenocarcinoma (EAC).

MATERIALS AND METHODS: Between October 2018 and December 2021, 60 women (mean age, 55 [range, 32-77] years) with EAC underwent preoperative pelvic MRI and HE4 level measurements. The positive enhancement integral (PEI), time to peak, maximum slope of increase (MSI), and maximum slope of decrease were measured by manually drawing a region of interest on the neoplastic tissue. The receiver operating characteristic curve was used to calculate the diagnostic efficiency of the single parameter and combined factors.

RESULTS: Lower apparent diffusion coefficients (ADCs) were observed in high-grade tumours (G3) than in low-grade tumours (G1/G2). PEI, MSI, and HE4 levels were higher in the high-grade tumours than in the low-grade tumours (p<0.05). The area under the curve (AUC) for G3 diagnosis using multiparametric MRI combined with HE4 was 0.929. ADC values were significantly lower in the EAC with LVSI than in those without LVSI. Tumours with LVSI showed higher PEI and HE4 levels than those without LVSI (p<0.05). The AUC for LVSI-positive diagnosis using multiparametric MRI combined with HE4 was 0.814.

CONCLUSION: Semi-quantitative DCE-MRI, ADC values, and serum HE4 levels can be used to predict tumour grade and LVSI, and the prediction efficiency of multiparametric MRI combined with serum HE4 is better than that of any single factor.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Yue, He, Wu, et al. Endometrioid adenocarcinoma: combined multiparametric MRI and tumour marker HE4 to evaluate tumour grade and lymphovascular space invasion. Clin Radiol. 2023. PMID: 37183140. doi:10.1016/j.crad.2023.04.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。