双层光谱CT可提高儿童脑部平扫CT的图像质量

Dual-layer spectral CT improves the image quality of cerebral unenhanced CT scan in children.
PubMed 文献 · Eur J Radiol · 2023-05-10

回顾性分析53例年龄≤12岁儿童的双层光谱探测器CT脑部平扫,比较常规图像与虚拟单能图像。低keV下噪声更优、100 keV噪声最低;45–75 keV的SNR和CNR显著更高;50 keV灰白质区分最佳、总体诊断质量最佳;100 keV颅下间隙和后颅窝伪影控制最佳。

要点

  • 儿童脑部平扫双层光谱CT中,50 keV的灰白质区分和总体诊断质量最佳。
  • 100 keV下颅下间隙和后颅窝线束硬化伪影控制最佳。
  • 45–75 keV虚拟单能图像的SNR和CNR显著高于常规图像。

核心结论

  • 与常规图像相比,虚拟单能图像显著改善儿童脑部图像质量;脑实质最佳能量为50 keV,颅下间隙和后颅窝最佳能量为100 keV。

研究设计与样本

  • 回顾性分析53例年龄≤12岁儿童的双层光谱探测器CT脑部平扫,重建常规图像和虚拟单能图像,由两名放射科医生独立采用5点Likert量表评分。

关键影像表现/征象

  • 低keV水平虚拟单能图像噪声优于常规图像,100 keV时噪声最低(P < 0.001)。
  • 45 keV至75 keV水平虚拟单能图像的SNR和CNR显著高于常规图像(P < 0.005)。
  • 50 keV的灰白质区分最佳,优于其他keV水平(P < 0.05)。
  • 100 keV的颅下间隙评估和后颅窝线束硬化伪影评估最佳。
  • 50 keV的总体诊断质量评估最佳(P < 0.013至P < 0.001)。

临床应用与阅片要点

  • 作者结论指出儿童脑实质评估最佳能量为50 keV,颅下间隙和后颅窝评估最佳能量为100 keV。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the image quality and determine the optimal energies of virtual monoenergetic imaging (VMI) in unenhanced pediatric cerebral scans by dual-layer spectral detector computed tomography (DLCT).

METHODS: Fifty-three consecutive unenhanced cerebral scans by a DLCT scanner in children (age ≤ 12 years) were retrospectively analyzed. Conventional images (CI) and VMIs were reconstructed. The gray matter (GM) and white matter (WM) noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), posterior fossa, and subcalvarial artifac tindex (PFAI, SAI) were calculated. Two radiologists independently determined the image quality using a 5-point Likert-type scale based on GM - WM differentiation (GWMA), subcalvarialspace (SAA), beam hardening artifacts in the posterior fossa (PFAA), and the overall diagnostic quality. The student t-test and Wilcoxon test were used to determining the statistical significance.

RESULTS: Compared with CI, superior noise were observed in VMI at low keV levels and were lowest at 100 keV (P < 0.001); the SNR and CNR were significantly higher at the 45 keV to 75 keV levels (all Ps of <0.005). The best GWMA were noticed at the 50 keV level compared to other keV levels (all P < 0.05). The optimal SAA and PFAA were found at 100 keV, respectively. The assessment of overall diagnostic quality was the best at 50 keV (P < 0.013 to < 0.001).

CONCLUSIONS: The VMI scan significantly improved the quality of pediatric cerebral images compared with those from CI. The optimal energy level for the brainparenchyma was 50 keV while those for subcalvarial space and posterior fossa were 100 keV.

来源:Eur J Radiol,查看原文。版权归原作者所有。