文献速递腹部泌尿生殖MR

基于深度学习重建与三维混合轮廓顺序技术的3T磁共振胰胆管成像:图像质量与采集时间评估

Deep learning-based reconstruction and 3D hybrid profile order technique for MRCP at 3T: evaluation of image quality and acquisition time.
PubMed 文献 · Eur Radiol · 2023-05-13

本回顾性研究纳入32例胆胰疾病患者,比较单次屏气三维混合轮廓顺序技术联合深度学习重建与呼吸门控下三维磁共振胰胆管成像的图像质量。结果显示,屏气联合深度学习重建的信噪比和对比噪声比显著高于呼吸门控,对比度和半高全宽低于呼吸门控,噪声、模糊和整体图像质量评分更高。

要点

  • 单次屏气三维混合轮廓顺序技术可在不降低空间分辨率的前提下完成磁共振胰胆管成像。
  • 深度学习重建可显著提高屏气磁共振胰胆管成像的对比噪声比和信噪比。
  • 屏气联合深度学习重建的模糊和整体图像质量评分高于呼吸门控。

核心结论

  • 三维混合轮廓顺序技术联合深度学习重建适用于单次屏气磁共振胰胆管成像,且不会导致3T磁共振图像质量和空间分辨率下降。
  • 考虑到其优势,该序列可能成为临床实践中磁共振胰胆管成像的标准方案,至少在3.0T条件下。

研究设计与样本

  • 回顾性研究,纳入32例胆胰疾病患者,在3T磁共振成像上行三维磁共振胰胆管成像。
  • 屏气图像分别采用和不采用深度学习重建,并与呼吸门控图像比较。
  • 定量评估胆总管信噪比、对比度、胆总管与胆管周围组织对比噪声比及胆总管半高全宽。
  • 由两名放射科医师采用4分制对图像噪声、对比度、伪影、模糊和整体图像质量进行评分。
  • 采用Friedman检验和事后Nemenyi检验比较定量与定性评分。

关键影像表现/征象

  • 屏气不联合深度学习重建与呼吸门控相比,信噪比和对比噪声比无显著差异。
  • 屏气联合深度学习重建的信噪比(p=0.013)和对比噪声比(p=0.027)显著高于呼吸门控。
  • 屏气联合和不联合深度学习重建的对比度(p<0.001)和半高全宽(p=0.015)均低于呼吸门控。
  • 屏气联合深度学习重建的模糊(p=0.003)和整体图像质量(p=0.008)评分高于呼吸门控。

诊断标准与关键数值

  • 采用4分制评估图像噪声、对比度、伪影、模糊和整体图像质量。
  • 定量指标包括信噪比、对比度、胆总管与胆管周围组织对比噪声比及胆总管半高全宽。

临床应用与阅片要点

  • 单次屏气三维混合轮廓顺序技术联合深度学习重建可用于磁共振胰胆管成像,不降低图像质量和空间分辨率。
  • 该序列可能成为临床实践中磁共振胰胆管成像的标准方案,至少在3.0T条件下。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the image quality of the 3D hybrid profile order technique and deep-learning-based reconstruction (DLR) for 3D magnetic resonance cholangiopancreatography (MRCP) within a single breath-hold (BH) at 3 T magnetic resonance imaging (MRI).

METHODS: This retrospective study included 32 patients with biliary and pancreatic disorders. BH images were reconstructed with and without DLR. The signal-to-noise ratio (SNR), contrast, contrast-to-noise ratio (CNR) between the common bile duct (CBD) and periductal tissues, and full width at half maximum (FWHM) of CBD on 3D-MRCP were evaluated quantitatively. Two radiologists scored image noise, contrast, artifacts, blur, and overall image quality of the three image types using a 4-point scale. Quantitative and qualitative scores were compared using the Friedman test and post hoc Nemenyi test.

RESULTS: The SNR and CNR were not significantly different when under respiratory gating- and BH-MRCP without DLR. However, they were significantly higher under BH with DLR than under respiratory gating (SNR, p = 0.013; CNR, p = 0.027). The contrast and FWHM of MRCP under BH with and without DLR were lower than those under respiratory gating (contrast, p < 0.001; FWHM, p = 0.015). Qualitative scores for noise, blur, and overall image quality were higher under BH with DLR than those under respiratory gating (blur, p = 0.003; overall, p = 0.008).

CONCLUSIONS: The combination of the 3D hybrid profile order technique and DLR is useful for MRCP within a single BH and does not lead to the deterioration of image quality and space resolution at 3 T MRI.

CLINICAL RELEVANCE STATEMENT: Considering its advantages, this sequence might become the standard protocol for MRCP in clinical practice, at least at 3.0 T.

KEY POINTS: • The 3D hybrid profile order can achieve MRCP within a single breath-hold without a decrease in spatial resolution. • The DLR significantly improved the CNR and SNR of BH-MRCP. • The 3D hybrid profile order technique with DLR reduces the deterioration of image quality in MRCP within a single breath-hold.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Shiraishi, Nakaura, Uetani, et al. Deep learning-based reconstruction and 3D hybrid profile order technique for MRCP at 3T: evaluation of image quality and acquisition time. Eur Radiol. 2023. PMID: 37178197. doi:10.1007/s00330-023-09703-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。