头颈部CT的迭代金属伪影减少技术有助于显示被牙科硬件伪影遮蔽的口腔癌和口咽癌
该回顾性研究纳入27例经组织学证实、在增强CT中被牙科伪影遮蔽的口腔癌或口咽癌患者,将原始CT数据分别采用iMAR强度1至5级及无iMAR(0级)重建。结果显示iMAR可改善肿瘤边缘与对比度的主观图像质量及肿瘤SNR和CNR,在4级和5级达到最佳(P<.001),伪影指数在5级降至最低(P<.001);肿瘤检出率在iMAR 5级较无iMAR提高2.4倍,4级提高2.1倍,3级提高1.9倍,但算法所致伪影随iMAR强度增加而显著增多(P<.05),5级最明显。
要点
- iMAR可改善被牙科伪影遮蔽的口腔癌和口咽癌CT的肿瘤边缘与对比度显示。
- 肿瘤SNR和CNR在iMAR 4级和5级最佳(P<.001),伪影指数在5级降至最低(P<.001)。
- 肿瘤检出率iMAR 5级较无iMAR提高2.4倍,但算法所致伪影在5级最明显。
核心结论
- iMAR可显著改善口腔癌和口咽癌的CT成像,主观与客观指标均证实,最高iMAR强度下效果最佳。
研究设计与样本
- 回顾性研究,纳入27例(女8例、男19例,平均年龄64±12.7岁)经组织学证实、增强CT中被牙科伪影遮蔽的口腔癌或口咽癌患者,原始CT数据分别行iMAR 1/2/3/4/5级及无iMAR(0级)重建。
关键影像表现/征象
- iMAR重建改善肿瘤边缘和对比度的主观图像质量。
- iMAR重建改善肿瘤SNR和CNR的客观参数。
- 算法所致伪影随iMAR强度升高而显著增多(P<.05),5级最明显。
诊断标准与关键数值
- 两名盲法放射科医师采用五点Likert量表对肿瘤可视性和伪影严重程度进行主观评分。
- 客观分析测定肿瘤SNR、CNR和伪影指数(AI)。
- 肿瘤SNR和CNR在iMAR 4级和5级达到最佳(P<.001),AI在iMAR 5级降至最低(P<.001)。
- 肿瘤检出率:iMAR 5级较无iMAR提高2.4倍,iMAR 4级提高2.1倍,iMAR 3级提高1.9倍。
临床应用与阅片要点
- 对牙科硬件伪影遮蔽的口腔癌和口咽癌CT,可采用iMAR重建改善肿瘤显示。
- iMAR 4级和5级下肿瘤SNR和CNR最佳,5级下伪影指数最低。
- iMAR强度越高算法所致伪影越明显(P<.05),5级达最大。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: The purpose of this study was to evaluate the diagnostic utility of iterative metal artifact reduction (iMAR) in computed tomography (CT)-imaging of oral and oropharyngeal cancers when obscured by dental hardware artifacts and to determine the most appropriate iMAR settings for this purpose.
MATERIALS AND METHODS: The study retrospectively enrolled 27 patients (8 female, 19 male; mean age 64±12.7years) with histologically confirmed oral or oropharyngeal cancer obscured by dental artifacts in contrast-enhanced CT. Raw CT data were reconstructed with ascending iMAR strengths (levels 1/2/3/4/5) and one reconstruction without iMAR (level 0). For subjective analysis, two blinded radiologists rated tumor visualization and artifact severity on a five-point Likert scale. For objective analysis, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and artifact index (AI) were determined.
RESULTS: iMAR reconstructions improved the subjective image quality of tumor edge and contrast, and the objective parameters of tumor SNR and CNR, reaching their optimum at iMAR levels 4 and 5 (P<.001). AI decreased with iMAR reconstructions reaching its minimum at iMAR level 5 (P<.001). Tumor detection rates increased 2.4-fold with iMAR 5, 2.1-fold with iMAR 4, and 1.9-fold with iMAR 3 compared to reconstructions without iMAR. Disadvantages such as algorithm-induced artifacts increased significantly with higher iMAR strengths (P<.05), reaching a maximum with iMAR 5.
CONCLUSION: iMAR significantly improves CT imaging of oral and oropharyngeal cancers, as confirmed by both subjective and objective measures, with best results at highest iMAR strengths.
引用
- Bayerl, May, Wuest, et al. Iterative Metal Artifact Reduction in Head and Neck CT Facilitates Tumor Visualization of Oral and Oropharyngeal Cancer Obscured by Artifacts From Dental Hardware. Acad Radiol. 2023. PMID: 37179206. doi:10.1016/j.acra.2023.04.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。