文献速递神经CT

双能CT评估血栓渗透性及其在急性缺血性卒中静脉溶栓后预后预测中的应用

Dual-energy CT in assessment of thrombus perviousness and its application in predicting outcomes after intravenous thrombolysis in acute ischemic stroke.
PubMed 文献 · Eur J Radiol · 2023-05-05

本研究纳入86例前循环近端颅内闭塞并接受静脉溶栓的急性缺血性卒中患者,用双能CT碘叠加图评估血栓渗透性。血栓碘浓度与常规渗透性参数显著相关,且与功能预后独立相关;标准化碘浓度预测良好预后AUC为0.755,优于任何常规渗透性参数。

要点

  • 双能CT碘叠加图可定量血栓碘浓度,与常规血栓渗透性参数显著相关。
  • 标准化碘浓度预测良好功能预后AUC为0.755,优于常规渗透性参数。
  • 血栓碘浓度与良好预后及成功再通独立相关,与最终梗死体积负相关。

核心结论

  • 双能CT在评估血栓渗透性方面有重要价值,标准化碘浓度是急性缺血性卒中静脉溶栓后卒中预后和再通的有意义预测指标。

研究设计与样本

  • 研究纳入86例前循环近端颅内闭塞并接受静脉溶栓的急性缺血性卒中患者,采用双能CT重建碘叠加图测量血栓碘浓度和标准化碘浓度,并与常规渗透性参数(血栓衰减增加、空隙分数ε和CTA指数)进行比较,通过Spearman相关和回归分析评估渗透性参数与结局的关联。

诊断标准与关键数值

  • 良好功能预后组血栓碘浓度中位数为6.81 mg/ml(四分位距4.76-8.73),不良预后组为3.52 mg/ml(四分位距2.08-6.86),组间P=0.001。
  • 良好功能预后组标准化碘浓度中位数为0.095(四分位距0.068-0.116),不良预后组为0.054(四分位距0.031-0.083),组间P<0.001。
  • 标准化碘浓度预测良好预后的AUC为0.755,高于任何常规渗透性参数(P<0.05)。
  • 多变量回归模型中,血栓碘浓度与良好预后独立相关(OR=1.472,95%CI:1.154-1.877,P=0.002),与成功再通独立相关(OR=1.356,95%CI:1.093-1.681,P=0.006)。
  • 血栓碘浓度与最终梗死体积负相关(r=-0.262,P=0.020),标准化碘浓度结果类似。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the feasibility of using iodine overlay maps reconstructed from dual-energy CT (DECT) to assess thrombus perviousness and investigate its value in predicting outcomes after intravenous thrombolysis in patients with acute ischemic stroke.

METHOD: 86 patients with proximal intracranial occlusions of the anterior circulation who underwent intravenous thrombolysis were included in this study. Thrombus iodine concentrations (ICthrombus) and normalized iodine concentrations (NICthrombus) were compared to conventional perviousness parameters (thrombus attenuation increase, TAI; void fraction, ε and CTA-index). The associations between perviousness parameters and outcomes were analyzed by Spearman's correlation and regression analysis.

RESULTS: ICthrombus and NICthrombus were significantly correlated with conventional perviousness parameters (P < 0.001). The median ICthrombus was 6.81 (interquartile range [IQR], 4.76-8.73) mg/ml in the favorable functional outcome group, which was higher than 3.52 (IQR, 2.08-6.86) mg/ml in the unfavorable outcome group (P = 0.001). The median NICthrombus was 0.095 (IQR, 0.068-0.116) and 0.054 (IQR, 0.031-0.083) in the favorable and unfavorable outcome groups, respectively (P < 0.001). NICthrombus predicted favorable outcome with a higher area under the curve (AUC) of 0.755 than any conventional perviousness parameter (P < 0.05). In the multivariable regression model, ICthrombus was independently associated with favorable outcome (odds ratio [OR] = 1.472, 95 % CI: 1.154-1.877, P = 0.002) and successful recanalization (OR = 1.356, 95 % CI: 1.093-1.681, P = 0.006). ICthrombus was negatively correlated with the final infarct volume (FIV) (r = -0.262, P = 0.020). Results for NICthrombus were similar.

CONCLUSIONS: DECT is of great value in assessing thrombus perviousness. NICthrombus is a meaningful predictor of stroke prognosis and recanalization after intravenous thrombolysis in acute ischemic stroke.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Dai, Xu, Fang, et al. Dual-energy CT in assessment of thrombus perviousness and its application in predicting outcomes after intravenous thrombolysis in acute ischemic stroke. Eur J Radiol. 2023. PMID: 37167682. doi:10.1016/j.ejrad.2023.110861

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。