文献速递妇产影像儿科影像心血管US

胎儿心脏筛查中的左室流出道:质量标准的引入在人工监督下并不总是与临床实践改善相关

The Left Outflow Tract in Fetal Cardiac Screening Examination: Introduction of Quality Criteria Is Not Always Associated With an Improvement of Practice When Supervised by Humans.
PubMed 文献 · J Ultrasound Med · 2023-05-10

本研究定义了7项胎儿左室流出道(LVOT)评估质量标准,并对三个中心在三个感兴趣时段进行人工审核。LVOT图像出现在超过94.3%的报告中,三个中心的平均质量评分分别为5.49/7(95%CI:5.36-5.62)、5.91/7(95%CI:5.80-6.03)和5.70/7(95%CI:5.58-5.82)。2017年与2020年比较,引入质量标准后差异无统计学意义(P=0.054)。

要点

  • LVOT图像在超过94.3%的超声报告中存在。
  • 三个中心三个时段的平均质量评分为5.49/7至5.91/7。
  • 引入质量标准后2017年与2020年比较差异无统计学意义(P=0.054)。

核心结论

  • 胎儿LVOT图像存在于大多数超声报告中,但在人工监督下引入所提出的质量标准似乎未与临床实践的显著改变相关。

研究设计与样本

  • 研究定义了7项胎儿LVOT评估质量标准,并从三个中心随机选取文件,在三个感兴趣时段进行人工审核,计算平均总评分和专项评分。

诊断标准与关键数值

  • 7项质量标准每项评分0至1分;三个中心三个时段的平均质量评分分别为5.49/7(95%CI:5.36-5.62)、5.91/7(95%CI:5.80-6.03)和5.70/7(95%CI:5.58-5.82),2017年与2020年比较P=0.054。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Since 2016, the French CNEOF included the left ventricular outflow tract (LVOT) in the second and third trimester of pregnancy in addition to the four-chamber view and the parasagittal view of the right outflow tract. The objective of this study was to define quality criteria for fetal LVOT assessment and to perform a human audit of past and current practices, before and after the implementation of those quality criteria at a large scale.

METHODS: Seven quality criteria were investigated and rated from 0 to 1 during three periods of interest. Files were randomly selected from three centers, and average total and specific scores were calculated.

RESULTS: LVOT pictures were present in more than 94.3% of reports. The average quality score was 5.49/7 (95% confidence interval [CI]: 5.36-5.62), 5.91/7 (95% CI: 5.80-6.03), and 5.70/7 (95% CI: 5.58-5.82) for the three centers in the three periods of interest. There was no significant difference following the introduction of the quality criteria, 2017 versus 2020, P = .054.

CONCLUSION: Fetal LVOT images were present in most of ultrasound reports but the introduction of the proposed quality criteria under human supervision seems not associated with a significant change in practice.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Regouin, Mancini, Lafouge, et al. The Left Outflow Tract in Fetal Cardiac Screening Examination: Introduction of Quality Criteria Is Not Always Associated With an Improvement of Practice When Supervised by Humans. J Ultrasound Med. 2023. PMID: 37163223. doi:10.1002/jum.16231

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。