文献速递骨肌神经技术与安全US

基于超声图像正中神经深度影像组学特征自动诊断腕管综合征:多中心研究

Deep Radiomics Features of Median Nerves for Automated Diagnosis of Carpal Tunnel Syndrome With Ultrasound Images: A Multi-Center Study.
PubMed 文献 · J Ultrasound Med · 2023-04-26

研究利用伊朗和哥伦比亚共416条正中神经超声图像,提取深度影像组学特征并筛选后输入9种机器学习算法,选出支持向量机和随机梯度下降两种最佳模型;内部验证AUC分别为0.910和0.908,外部验证均为0.890,表现一致,作者认为该系统可用于医院和综合诊所的临床使用。

要点

  • 基于正中神经超声深度影像组学特征的支持向量机模型内部验证AUC 0.910,外部验证AUC 0.890。
  • 随机梯度下降模型内部验证AUC 0.908,外部验证AUC 0.890,与支持向量机模型表现一致。
  • 作者认为该人工智能系统可用于医院和综合诊所的临床使用。

核心结论

  • 基于深度影像组学特征的人工智能模型在内部和外部数据集中表现一致,作者认为该系统可用于医院和综合诊所的临床使用。

研究设计与样本

  • 多中心研究,使用伊朗和哥伦比亚2个国家的416条正中神经超声图像;开发集为伊朗112条卡压神经和112条正常神经,验证集为伊朗26条卡压神经和26条正常神经及哥伦比亚70条卡压神经和70条正常神经;超声图像输入SqueezNet架构提取深度影像组学特征,经ReliefF方法筛选后输入9种机器学习算法选择最佳分类器,并对表现最好的2个模型进行外部验证。

诊断标准与关键数值

  • 支持向量机模型内部验证AUC 0.910(敏感度88.46%,特异度88.46%),外部验证AUC 0.890(敏感度85.71%,特异度82.86%);随机梯度下降模型内部验证AUC 0.908(敏感度84.62%,特异度88.46%),外部验证AUC 0.890(敏感度84.29%,特异度82.86%)。

临床应用与阅片要点

  • 作者认为该人工智能系统可用于医院和综合诊所的临床使用。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Ultrasound is widely used in diagnosing carpal tunnel syndrome (CTS). However, the limitations of ultrasound in CTS detection are the lack of objective measures in the detection of nerve abnormality and the operator-dependent nature of ultrasound imaging. Therefore, in this study, we developed and proposed externally validated artificial intelligence (AI) models based on deep-radiomics features.

METHODS: We have used 416 median nerves from 2 countries (Iran and Colombia) for the development (112 entrapped and 112 normal nerves from Iran) and validation (26 entrapped and 26 normal nerves from Iran, and 70 entrapped and 70 normal nerves from Columbia) of our models. Ultrasound images were fed to the SqueezNet architecture to extract deep-radiomics features. Then a ReliefF method was used to select the clinically significant features. The selected deep-radiomics features were fed to 9 common machine-learning algorithms to choose the best-performing classifier. The 2 best-performing AI models were then externally validated.

RESULTS: Our developed model achieved an area under the receiver operating characteristic (ROC) curve (AUC) of 0.910 (88.46% sensitivity, 88.46% specificity) and 0.908 (84.62% sensitivity, 88.46% specificity) with support vector machine and stochastic gradient descent (SGD), respectively using the internal validation dataset. Furthermore, both models consistently performed well in the external validation dataset, and achieved an AUC of 0.890 (85.71% sensitivity, 82.86% specificity) and 0.890 (84.29% sensitivity and 82.86% specificity), with SVM and SGD models, respectively.

CONCLUSION: Our proposed AI models fed with deep-radiomics features performed consistently with internal and external datasets. This justifies that our proposed system can be employed for clinical use in hospitals and polyclinics.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Mohammadi, Torres-Cuenca, Mirza-Aghazadeh-Attari, et al. Deep Radiomics Features of Median Nerves for Automated Diagnosis of Carpal Tunnel Syndrome With Ultrasound Images: A Multi-Center Study. J Ultrasound Med. 2023. PMID: 37159483. doi:10.1002/jum.16244

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。