文献速递腹部技术与安全US

超声肝脏脂肪定量:衰减系数的深度依赖性

Liver Fat Quantification With Ultrasound: Depth Dependence of Attenuation Coefficient.
PubMed 文献 · J Ultrasound Med · 2023-04-26

这项回顾性双中心研究评估了不同深度对多厂商超声衰减系数(AC)的影响,并分析感兴趣区(ROI)大小对AC测量的影响。结果显示所有厂商的AC值均随深度增加而降低,1 cm ROI的AC值显著高于3 cm ROI,但不同ROI大小之间的一致性极好(CCC 0.82)。结论指出AC测量存在深度依赖性,需要标准化固定ROI深度和大小。

要点

  • AC值随深度每增加1 cm而降低,不同厂商的下降系数不同。
  • 1 cm ROI的AC值显著高于3 cm ROI,但一致性极好(CCC 0.82)。
  • 建议采用固定ROI深度和大小的标准化协议进行AC测量。

核心结论

  • AC测量存在深度依赖性并影响结果,需要标准化固定ROI深度和大小的协议。

研究设计与样本

  • 回顾性、双中心研究,经IRB批准并符合HIPAA;使用AC-Canon和AC-Philips算法,并从超声衍生脂肪分数算法中提取AC-Siemens值。

临床应用与阅片要点

  • 作者认为需要采用固定ROI深度和大小的标准化协议进行AC测量。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The primary aim was to estimate the influence of various depths on ultrasound attenuation coefficient (AC) of multiple vendors in the liver. The secondary aim was to evaluate the impact of region of interest (ROI) size on AC measurements in a subset of participants.

METHODS: This Institutional Review Board (IRB)-approved Health Insurance Portability and Accountability Act (HIPAA)-compliant retrospective study was carried out in two centers using AC-Canon and AC-Philips algorithms and extracting AC-Siemens values from ultrasound-derived fat fraction algorithm. Measurements were performed positioning ROI upper edge (3 cm size) at 2, 3, 4, 5 cm from the liver capsule with AC-Canon and AC-Philips and at 1.5, 2, 3 cm with Siemens algorithm. In a subset of participants, measurements were obtained with 1 and 3 cm ROI size. Univariate and multivariate linear regression models and Lin's concordance correlation coefficient (CCC) were used for statistical analysis as appropriate.

RESULTS: Three different cohorts were studied. Sixty-three participants (34 females; mean age: 51 ± 14 years) were studied with AC-Canon, 60 (46 females; mean age: 57 ± 11 years) with AC-Philips, and 50 (25 females; 61 ± 13 years) with AC-Siemens. There was a decrease in AC values per 1 cm increase in depth in all. In multivariable analysis, the coefficient was -0.049 (-0.060; -0.038 P < .001) with AC-Canon, -0.058 (-0.066; -0.049 P < .001) with AC-Philips and -0.081 (-0.112; -0.050 P < .001) with AC-Siemens. AC values with 1 cm ROI were significantly higher than those obtained with 3 cm ROI at all depths (P < .001) but the agreement between AC values obtained with different ROI size was excellent (CCC 0.82 [0.77-0.88]).

CONCLUSIONS: There is depth dependence in AC measurement that affects results. A standardized protocol with fixed ROI's depth and size is needed.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Ferraioli, Raimondi, Maiocchi, et al. Liver Fat Quantification With Ultrasound: Depth Dependence of Attenuation Coefficient. J Ultrasound Med. 2023. PMID: 37159490. doi:10.1002/jum.16242

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。