文献速递腹部技术与安全CT

整合管腔与肠系膜特征的放射组学模型预测克罗恩病患者黏膜活动度与手术风险:多中心研究

A Novel Radiomics Model Integrating Luminal and Mesenteric Features to Predict Mucosal Activity and Surgery Risk in Crohn's Disease Patients: A Multicenter Study.
PubMed 文献 · Acad Radiol · 2023-05-05

本研究纳入三个中心共167例克罗恩病患者,基于CT小肠造影提取管腔与肠系膜的放射组学及形态学特征,构建SVM分类器评估SES-CD分级和识别中重度SES-CD,并建立结合图像评分与临床数据的列线图预测手术进展。融合影像模型在验证队列识别中重度SES-CD的AUC为0.896(95%CI 0.812-0.960)。

要点

  • 融合管腔与肠系膜放射组学特征的多分类SES-CD模型训练集AUC 0.828、验证集AUC 0.709。
  • 融合放射组学与形态学特征的图像融合模型识别中重度SES-CD:训练集AUC 0.847(95%CI 0.784-0.902),验证集AUC 0.896(95%CI 0.812-0.960)。
  • 基于多变量Cox分析构建的列线图可预测CD患者间隔手术时间。

核心结论

  • 整合管腔与肠系膜放射组学特征构建无创分级模型评估CD黏膜活动度具有可行性,融合图像评分结合临床数据可能为预测手术时间提供准确的预后模型。

研究设计与样本

  • 多中心研究,纳入三个中心共167例克罗恩病患者,基于CT小肠造影提取放射组学与图像形态学特征量化节段性和整体SES-CD,采用基于图像融合的支持向量机分类器进行SES-CD分级并识别中重度SES-CD,以AUC评估预测模型性能,并通过多变量Cox分析构建结合sum-image评分与临床数据的列线图预测手术进展。

诊断标准与关键数值

  • 基于管腔与肠系膜放射组学组合的多分类节段性SES-CD融合放射组学模型AUC:训练队列0.828,验证队列0.709。
  • 整合融合放射组学与形态学特征的图像融合模型识别中重度SES-CD的AUC:训练队列0.847(95%CI 0.784-0.902),验证队列0.896(95%CI 0.812-0.960)。

临床应用与阅片要点

  • 基于CT小肠造影提取管腔与肠系膜放射组学及形态学特征,可用于无创评估CD黏膜活动度。
  • 融合图像评分结合临床数据构建的列线图可用于预测CD患者手术时间。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: To investigate the feasibility of integrating radiomics and morphological features based on computed tomography enterography (CTE) for developing a noninvasive grading model for mucosal activity and surgery risk of Crohn's disease (CD) patients.

METHODS: A total of 167 patients from three centers were enrolled. Radiomics and image morphological features were extracted to quantify segmental and global simple endoscopic score for Crohn's disease (SES-CD). An image-fusion-based support vector machine (SVM) classifier was used for grading SES-CD and identifying moderate-to-severe SES-CD. The performance of the predictive model was assessed using the area under the receiver operating characteristic curve (AUC). A multiparametric model was developed to predict surgical progression in CD patients by combining sum-image scores and clinical data.

RESULTS: The AUC values of the multicategorical segmental SES-CD fusion radiomic model based on a combination of luminal and mesenteric radiomics were 0.828 and 0.709 in training and validation cohorts. The image fusion model integrating the fusion radiomics and morphological features could accurately distinguish bowel segments with moderate-to-severe SES-CD in both the training cohort (AUC = 0.847, 95% confidence interval (CI): 0.784-0.902) and the validation cohort (AUC = 0.896, 95% CI: 0.812-0.960). A predictive nomogram for interval surgery was developed based on multivariable cox analysis.

CONCLUSIONS: This study demonstrated the feasibility of integrating lumen and mesentery radiomic features to develop a promising noninvasive grading model for mucosal activity of CD. In combination with clinical data, the fusion-image score may yield an accurate prognostic model for time to surgery.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Ruiqing, Jing, Shunli, et al. A Novel Radiomics Model Integrating Luminal and Mesenteric Features to Predict Mucosal Activity and Surgery Risk in Crohn's Disease Patients: A Multicenter Study. Acad Radiol. 2023. PMID: 37149448. doi:10.1016/j.acra.2023.03.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。