文献速递骨肌技术与安全US

动态肌肉诱导负荷下人体自由跟腱局部形变的超声测量:系统综述

Ultrasound Measurement of Local Deformation in the Human Free Achilles Tendon Produced by Dynamic Muscle-Induced Loading: A Systematic Review.
PubMed 文献 · Ultrasound Med Biol · 2023-05-04

该系统综述遵循PRISMA指南检索四个数据库,纳入13篇研究,评估自由跟腱在体组织水平形变。证据一致显示健康年轻跟腱呈非均匀形变,深层位移比浅层多18%-80%;非均匀性随年龄增长降低12%-85%,存在损伤时降低42%-91%。

要点

  • 健康年轻跟腱在动态负荷下呈非均匀形变,深层位移比浅层多18%-80%。
  • 跟腱形变非均匀性随年龄增长降低12%-85%,损伤时降低42%-91%。
  • 动态负荷下跟腱形变模式可能作为肌腱健康、损伤风险及康复效果的生物标志物。

核心结论

  • 有限的大效应量证据表明,动态负荷下跟腱形变模式呈非均匀性,可能作为肌腱健康、损伤风险及康复效果的生物标志物。

研究设计与样本

  • 系统综述,遵循PRISMA指南系统检索PubMed、Embase、Scopus和Web of Science,最终纳入13篇文章,其中7篇为高质量研究、6篇为中等质量研究,并评估了研究质量和偏倚风险。

关键影像表现/征象

  • 健康年轻跟腱在动态肌肉诱导负荷下呈非均匀形变,深层位移比浅层多18%-80%。
  • 跟腱形变非均匀性随年龄增长降低12%-85%。
  • 存在损伤时跟腱形变非均匀性降低42%-91%。

临床应用与阅片要点

  • 超声测量自由跟腱组织水平形变时需关注跨肌腱宽度的非均匀形变模式,尤其是深层与浅层位移差异。
  • 作者认为改善参与者招募和测量流程可提高研究质量,以探索不同人群中肌腱结构、功能、衰老与疾病的联系。

局限性

  • 仅有限证据支持跟腱形变模式作为生物标志物,效应量大但证据有限。
  • 作者指出需改善参与者招募和测量流程以提高研究质量。
  • 作者指出需在 distinct populations 中探索肌腱结构、功能、衰老与疾病的联系。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Achilles tendinopathy is the most prevalent lower limb tendinopathy, yet it remains poorly understood, with mismatches between observed structure and reported function. Recent studies have hypothesised that Achilles tendon (AT) healthy function is associated with variable deformation across the tendon width during use, focusing on quantifying sub-tendon deformation. Here, the aim of this work was to synthesise recent advances exploring human free AT tissue-level deformation during use. Following PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines, PubMed, Embase, Scopus and Web of Science were systematically searched. Study quality and risk of bias were assessed. Thirteen articles were retained, yielding data on free AT deformation patterns. Seven were categorised as high-quality and six as medium-quality studies. Evidence consistently reports that healthy and young tendons deform non-uniformly, with the deeper layer displacing 18%-80% more than the superficial layer. Non-uniformity decreased by 12%-85% with increasing age and by 42%-91% in the presence of injury. There is limited evidence of large effect that AT deformation patterns during dynamic loading are non-uniform and may act as a biomarker of tendon health, risk of injury and rehabilitation impact. Better considered participant recruitment and improved measurement procedures would particularly improve study quality, to explore links between tendon structure, function, aging and disease in distinct populations.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Shivapatham, Richards, Bamber, et al. Ultrasound Measurement of Local Deformation in the Human Free Achilles Tendon Produced by Dynamic Muscle-Induced Loading: A Systematic Review. Ultrasound Med Biol. 2023. PMID: 37149429. doi:10.1016/j.ultrasmedbio.2023.03.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。