文献速递腹部儿科影像MR

高b值合成扩散加权成像在儿童腹部MRI中的可靠性

Reliability of synthetic diffusion-weighted imaging with a high b-value for paediatric abdominal MRI.
PubMed 文献 · Clin Radiol · 2023-04-22

回顾性纳入30例接受肝脏或胰胆管MRI的儿童患者,采用10个b值生成b=1500 s/mm²的合成DWI,并与常规DWI比较肝脏、脾脏、椎旁肌肉及肿块的信号和ADC值;常规与合成DWI及ADC在肝脏、脾脏和肌肉的ICC为0.906-0.995,肿块病灶的ICC为0.997-0.999,显示高度一致。

要点

  • 儿童腹部MRI中,b=1500 s/mm²合成DWI与常规DWI在肝脏、脾脏、肌肉和肿块病灶的ICC均高(0.906-0.999)。
  • 肿块病灶的合成DWI和ADC的ICC均为0.997-0.999,一致性极好。
  • 合成DWI可自动生成高b值图像,无需额外采集。

核心结论

  • 高b值合成的DWI和ADC值在儿童MRI的肝脏、脾脏、肌肉和肿块中与常规DWI显示极好的一致性。

研究设计与样本

  • 回顾性研究,纳入2021年3月至10月接受肝脏或胰胆管MRI的儿童患者(<19岁)30例(男22例、女8例,平均10.8±3.1岁),使用10个b值(b=0、25、50、75、100、200、400、600、800、1500 s/mm²)采集DWI,通过软件自动生成b=1500 s/mm²的合成DWI,以常规DWI为参考,采用单指数模型计算ADC值,计算组内相关系数(ICC)评估可靠性。

关键影像表现/征象

  • 4例患者腹部MRI发现肿瘤。
  • 肝脏、脾脏和肌肉的常规与合成DWI及ADC(b=1500 s/mm²)ICC为0.906-0.995。
  • 肿块病灶的合成DWI和ADC图像ICC均为0.997-0.999。

诊断标准与关键数值

  • 采用ICC评估常规与合成DWI及ADC值的一致性:肝脏、脾脏和肌肉的ICC为0.906-0.995;肿块病灶的ICC为0.997-0.999。
  • ADC值通过单指数模型计算,b=1500 s/mm²。

临床应用与阅片要点

  • 在儿童腹部MRI中,合成DWI可自动生成b=1500 s/mm²的高b值图像,其信号和ADC值与常规DWI高度一致。
  • 阅片时可参考合成DWI评估肝脏、脾脏、肌肉及肿块病灶,但需注意本研究样本量有限(30例,其中4例有肿瘤)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the reliability of synthetic diffusion-weighted imaging (DWI) using a high b-value in comparison to conventional DWI for paediatric abdominal MRI.

MATERIALS AND METHODS: Paediatric patients (<19 years old) who underwent liver or pancreatobiliary MRI with DWI using 10 b-values (b = 0, 25, 50, 75, 100, 200, 400, 600, 800, 1,500 s/mm2) from March to October 2021 were included in this retrospective study. Using the software, synthetic DWI using b = 1,500 s/mm2 was generated automatically by selecting the b-value required as output. Conventional and synthetic DWI values for b = 1,500 s/mm2 were measured at the liver, spleen, paraspinal muscle, and mass lesions, if present, and apparent diffusion coefficient (ADC) values were calculated using the mono-exponential model. Intraclass correlation coefficients (ICCs) were calculated to assess the reliability of conventional and synthetic DWI and ADC values with b = 1,500 s/mm2.

RESULTS: Thirty paediatric patients (M:F = 22:8, mean 10.8 ± 3.1 years old) were included and four had tumours on abdominal MRI. ICC values were 0.906-0.995 between conventional and synthetic DWI and ADC with b = 1,500 s/mm2 in the liver, spleen and muscle. For mass lesions, ICC values were 0.997-0.999 for both synthetic DWI and ADC images.

CONCLUSIONS: Synthetic DWI and ADC values obtained using a high b-value showed excellent agreement with conventional DWI for the liver, spleen, muscle, and mass in paediatric MRI.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Shin, Son, Hwang, et al. Reliability of synthetic diffusion-weighted imaging with a high b-value for paediatric abdominal MRI. Clin Radiol. 2023. PMID: 37149417. doi:10.1016/j.crad.2023.04.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。