文献速递心血管技术与安全CTMR

基于深度学习的CT后处理降噪用于冠状动脉周围脂肪衰减指数

Deep Learning-based Post Hoc CT Denoising for the Coronary Perivascular Fat Attenuation Index.
PubMed 文献 · Acad Radiol · 2023-03-02

本研究回顾性纳入43例同时行冠状动脉CT血管成像(CCTA)和冠状动脉斑块MRI的患者,利用残差密集网络对标准CCTA图像进行降噪生成高保真图像,并以MRI显示的高强度出血性斑块(HIPs)为参考标准,比较降噪前后FAI的诊断性能。降噪后FAI的AUC从0.77(95%CI 0.62-0.91)提高至0.89(95%CI 0.78-0.99),差异有统计学意义(P=0.008)。

要点

  • 降噪后CCTA的FAI预测HIPs的AUC为0.89,高于原图的0.77(P=0.008)。
  • 降噪后FAI预测HIPs的最佳阈值为-69 HU,敏感度0.85、特异度0.79、准确率0.80。
  • FAI测量范围为右冠状动脉近段外壁径向距离内-190至-30 HU体素的平均CT值。

核心结论

  • 基于深度学习的降噪高保真CCTA提高了FAI预测高强度出血性斑块的AUC和特异度。

研究设计与样本

  • 回顾性研究,纳入43例同时行CCTA和冠状动脉斑块MRI的患者;使用残差密集网络对标准CCTA图像降噪,以MRI定义的高强度出血性斑块为参考标准。

诊断标准与关键数值

  • FAI为右冠状动脉近段外壁径向距离内-190至-30 HU所有体素的平均CT值;降噪后CCTA预测HIPs的最佳阈值为-69 HU,敏感度0.85(11/13)、特异度0.79(25/30)、准确率0.80(36/43);降噪后FAI的AUC为0.89(95%CI 0.78-0.99),原图FAI的AUC为0.77(95%CI 0.62-0.91),P=0.008。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Coronary inflammation related to high-risk hemorrhagic plaques can be captured by the perivascular fat attenuation index (FAI) using coronary computed tomography angiography (CCTA). Since the FAI is susceptible to image noise, we believe deep learning (DL)-based post hoc noise reduction can improve diagnostic capability. We aimed to assess the diagnostic performance of the FAI in DL-based denoised high-fidelity CCTA images compared with coronary plaque magnetic resonance imaging (MRI) delivered high-intensity hemorrhagic plaques (HIPs).

MATERIALS AND METHODS: We retrospectively reviewed 43 patients who underwent CCTA and coronary plaque MRI. We generated high-fidelity CCTA images by denoising the standard CCTA images using a residual dense network that supervised the denoising task by averaging three cardiac phases with nonrigid registration. We measured the FAIs as the mean CT value of all voxels (range of -190 to -30 HU) located within a radial distance from the outer proximal right coronary artery wall. The diagnostic reference standard was defined as HIPs (high-risk hemorrhagic plaques) using MRI. The diagnostic performance of the FAI in the original and denoised images was assessed using receiver operating characteristic curves.

RESULTS: Of 43 patients, 13 had HIPs. The denoised CCTA improved the area under the curve (0.89 [95% confidence interval (CI) 0.78-0.99]) of the FAI compared with that in the original image (0.77 [95% CI, 0.62-0.91], p = 0.008). The optimal cutoff value for predicting HIPs in denoised CCTA was -69 HU with 0.85 (11/13) sensitivity, 0.79 (25/30) specificity, and 0.80 (36/43) accuracy.

CONCLUSION: DL-based denoised high-fidelity CCTA improved the AUC and specificity of the FAI for predicting HIPs.

来源:Acad Radiol,查看原文。版权归原作者所有。