基于CT影像组学的结缔组织病相关间质性肺疾病性别-年龄-生理分期预测模型
回顾性分析184例结缔组织病相关间质性肺疾病患者的胸部CT,按性别、年龄和肺功能结果进行GAP分期(GAP I期137例、II期36例、III期11例),将II期和III期合并后按7:3随机分为训练组和测试组,提取影像组学特征建立模型并构建列线图。影像组学模型区分GAP I期与II/III期的训练组AUC为0.803(95%CI 0.724-0.874)、测试组AUC为0.801(95%CI 0.663-0.912);结合年龄和性别的列线图模型在训练组(88.4% vs. 82.1%)和测试组(83.3% vs. 79.2%)准确率均提高。
要点
- 影像组学模型可区分CTD-ILD的GAP I期与GAP II/III期,训练组AUC 0.803、测试组AUC 0.801。
- 联合年龄和性别的列线图模型准确率高于单纯影像组学模型:训练组88.4% vs. 82.1%,测试组83.3% vs. 79.2%。
- 共筛选出4个显著影像组学特征用于构建模型。
核心结论
- 基于胸部CT的影像组学方法可用于评估CTD-ILD患者的疾病严重程度,列线图模型预测GAP分期的性能更优。
研究设计与样本
- 回顾性分析184例CTD-ILD患者的胸部CT图像,依据性别、年龄和肺功能检查结果进行GAP分期,GAP I、II、III期分别为137、36、11例;将GAP II期和III期合并为一组,两组患者按7:3比例随机分为训练组和测试组;使用AK软件提取影像组学特征,经多变量逻辑回归分析建立影像组学模型,并基于Rad-score与临床因素(年龄和性别)建立列线图模型。
诊断标准与关键数值
- 影像组学模型选取4个显著影像组学特征构建,区分GAP I期与GAP II/III期的训练组AUC=0.803(95%CI 0.724-0.874)、测试组AUC=0.801(95%CI 0.663-0.912);列线图模型联合临床因素与影像组学特征,训练组准确率88.4% vs. 影像组学模型82.1%,测试组准确率83.3% vs. 影像组学模型79.2%。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To analyze the feasibility of predicting gender-age-physiology (GAP) staging in patients with connective tissue disease-associated interstitial lung disease (CTD-ILD) by radiomics based on computed tomography (CT) of the chest.
MATERIALS AND METHODS: Chest CT images of 184 patients with CTD-ILD were retrospectively analyzed. GAP staging was performed on the basis of gender, age, and pulmonary function test results. GAP I, II, and III have 137, 36, and 11 cases, respectively. The cases in GAP Ⅱ and Ⅲ were then combined into one group, and the two groups of patients were randomly divided into the training and testing groups with a 7:3 ratio. The radiomics features were extracted using AK software. Multivariate logistic regression analysis was then conducted to establish a radiomics model. A nomogram model was established on the basis of Rad-score and clinical factors (age and gender).
RESULTS: For the radiomics model, four significant radiomics features were selected to construct the model and showed excellent ability to differentiate GAP I from GAP Ⅱ and Ⅲ in both the training group (the area under the curve [AUC] = 0.803, 95% confidence interval [CI]: 0.724-0.874) and testing group (AUC = 0.801, 95% CI:0.663-0.912). The nomogram model that combined clinical factors and radiomics features improved higher accuracy of both training (88.4% vs. 82.1%) and testing (83.3% vs. 79.2%).
CONCLUSION: The disease severity assessment of patients with CTD-ILD can be evaluated by applying the radiomics method based on CT images. The nomogram model demonstrates better performance for predicting the GAP staging.
引用
- Jiang, Su, Quan, et al. Computed Tomography Radiomics-based Prediction Model for Gender-Age-Physiology Staging of Connective Tissue Disease-associated Interstitial Lung Disease. Acad Radiol. 2023. PMID: 36868880. doi:10.1016/j.acra.2023.01.038
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。