文献速递神经MR

结合半定量评级与自动脑容量测量在疑似行为变异型额颞叶痴呆MRI评估中的价值:对临床实践有附加价值吗?

Combining semi-quantitative rating and automated brain volumetry in MRI evaluation of patients with probable behavioural variant of fronto-temporal dementia: an added value for clinical practise?
PubMed 文献 · Neuroradiology · 2023-03-03

本研究对112例受试者的3D-T1脑MRI由3名神经放射科医生用Kipps半定量量表进行脑萎缩分级并识别提示bvFTD的萎缩模式,同时用Quantib® ND和Icometrix®两种自动软件做定量萎缩评估,再行半定量与定量联合评估。结果显示联合评估可减少不同阅片者之间在bvFTD神经影像诊断中的差异,部分阅片者诊断准确率提高(AUC达0.971–0.977,P<0.001),但并非所有阅片者均获益。

要点

  • 3名阅片者半定量诊断bvFTD的Kappa值分别为0.881、0.867、0.741, observer间一致性良好至中等。
  • 半定量萎缩分级与Icometrix®体积值呈中度相关,与Quantib® ND呈弱相关。
  • 联合自动定量后,阅片者1和3诊断bvFTD的AUC分别提高至0.974和0.971–0.977(P<0.001),阅片者2无改善。

核心结论

  • 联合半定量与定量脑影像评估可减少不同阅片者在bvFTD神经影像诊断工作中的差异。

研究设计与样本

  • 对112例受试者的3D-T1脑MRI进行诊断评估研究,由3名神经放射科医生使用Kipps半定量评定量表定义脑萎缩分级并识别提示bvFTD的萎缩模式,定量萎缩评估采用Quantib® ND和Icometrix®两种自动软件。

关键影像表现/征象

  • 3名神经放射科医生在3D-T1脑MRI上使用Kipps半定量评定量表定义脑萎缩分级并识别提示bvFTD的萎缩模式。
  • 半定量萎缩分级与Icometrix®计算的体积值呈中度相关,与Quantib® ND计算的体积值呈弱相关。

诊断标准与关键数值

  • 阅片者诊断bvFTD的Kappa值:阅片者1为0.881,阅片者2为0.867,阅片者3为0.741。
  • 使用Icometrix®软件定义提示bvFTD的神经放射学征象时,阅片者1的AUC为0.974,阅片者3的AUC为0.971(P<0.001)。
  • 使用Quantib® ND软件定义提示bvFTD的神经放射学征象时,阅片者1的AUC为0.974,阅片者3的AUC为0.977(P<0.001)。
  • 联合评估对阅片者2的诊断准确率未见改善。

临床应用与阅片要点

  • 在bvFTD的神经影像诊断工作中,可联合半定量评定量表与自动脑容量测量软件进行萎缩评估。
  • 联合评估可能有助于减少不同阅片者之间的诊断差异,但改善程度因阅片者而异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the diagnostic value of combined semiquantitative and quantitative assessment of brain atrophy in the diagnostic workup of the behavioural-variant of frontotemporal dementia (bvFTD).

METHODS: Three neuroradiologists defined brain atrophy grading and identified atrophy pattern suggestive of bvFTD on 3D-T1 brain MRI of 112 subjects using a semiquantitative rating scale (Kipps'). A quantitative atrophy assessment was performed using two different automated software (Quantib® ND and Icometrix®). A combined semiquantitative and quantitative assessment of brain atrophy was made to evaluate the improvement in brain atrophy grading to identify probable bvFTD patients.

RESULTS: Observers' performances in the diagnosis of bvFTD were very good for Observer 1 (k value = 0.881) and 2 (k value = 0.867), substantial for Observer 3 (k value = 0.741). Semiquantitative atrophy grading of all the observers showed a moderate and a poor correlation with the volume values calculated by Icometrix® and by Quantib® ND, respectively. For the definition of neuroradiological signs presumptive of bvFTD, the use of Icometrix® software improved the diagnostic accuracy for Observer 1 resulting in an AUC of 0.974, and for Observer 3 resulting in a AUC of 0.971 (p-value < 0.001). The use of Quantib® ND software improved the diagnostic accuracy for Observer 1 resulting in an AUC of 0.974, and for Observer 3 resulting in a AUC of 0.977 (p-value < 0.001). No improvement was observed for Observer 2.

CONCLUSION: Combining semiquantitative and quantitative brain imaging evaluation allows to reduce discrepancies in the neuroradiological diagnostic workup of bvFTD by different readers.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Calloni, Vezzulli, Castellano, et al. Combining semi-quantitative rating and automated brain volumetry in MRI evaluation of patients with probable behavioural variant of fronto-temporal dementia: an added value for clinical practise? Neuroradiology. 2023. PMID: 36867204. doi:10.1007/s00234-023-03133-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。