时间分辨MR血管成像在脊髓动静脉分流中的高诊断效能
本研究纳入100例疑似脊髓动静脉分流(SAVS)患者,术前接受优化扫描参数的时间分辨MR血管成像(TR-MRA)后行数字减影血管造影(DSA)。最终97例中80例(82.5%)经TR-MRA诊断并分型,与DSA分型一致性极好(κ=0.91);TR-MRA诊断SAVS的敏感度100%、特异度76.5%、准确率95.9%。
要点
- TR-MRA诊断SAVS敏感度100%(95%CI 94.3-100.0%),特异度76.5%(95%CI 49.8-92.2%)。
- TR-MRA与DSA对SAVS分型一致性极好(κ=0.91)。
- TR-MRA对供血动脉检出准确率在脊髓硬膜动静脉分流中达91.7%。
核心结论
- 时间分辨MR血管成像对SAVS筛查具有极好的诊断效能,并能对SAVS分型,对脊髓硬膜动静脉分流中的供血动脉识别具有高诊断准确率。
研究设计与样本
- 纳入100例疑似SAVS患者,每例术前接受优化扫描参数的TR-MRA后行DSA;最终97例纳入分析,以DSA为参考标准。
诊断标准与关键数值
- TR-MRA诊断SAVS的敏感度100%(95%CI 94.3-100.0%)、特异度76.5%(95%CI 49.8-92.2%)、阳性预测值95.2%(95%CI 87.6-98.5%)、阴性预测值100%(95%CI 71.7-100.0%)、准确率95.9%(95%CI 89.9-98.4%);TR-MRA与DSA分型一致性κ=0.91;供血动脉检出准确率在脊髓髓周动静脉分流为75.9%、脊髓硬膜动静脉分流为91.7%、脊髓硬膜外动静脉分流为80.0%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: In comparison with the limited efficacy of conventional MR imaging and the invasiveness of catheter-based digital subtraction angiography (DSA), time-resolved MR angiography (TR-MRA) has been proposed as a promising examination for early diagnosis of spinal arteriovenous shunts (SAVSs). This paper aims to investigate the diagnostic performance of TR-MRA with scan parameters optimized for SAVSs evaluation in a large number of patients.
METHODS: One hundred patients with suspected SAVSs were enrolled. Each patient underwent preoperative TR-MRA with optimized scan parameters followed by DSA. The presence or absence of SAVS, the types and the angioarchitecture of SAVSs in the TR-MRA images were diagnostically analyzed.
RESULTS: Among the final 97 patients, 80 cases (82.5 %) were diagnosed and classified by TR-MRA as spinal cord arteriovenous shunts (SCAVSs; n = 22), spinal dural arteriovenous shunts (SDAVSs; n = 48), and spinal extradural arteriovenous shunts (SEDAVSs; n = 10). The agreement for classifying SAVSs between TR-MRA and DSA was excellent (κ = 0.91). The sensitivity, specificity, PPV, NPV, and accuracy of TR-MRA for the diagnosis of SAVSs were 100 % (95 % CI, 94.3-100.0 %), 76.5 % (95 % CI, 49.8-92.2 %), 95.2 % (95 % CI, 87.6-98.5 %), 100 % (95 % CI, 71.7-100.0 %), and 95.9 % (95 % CI, 89.9-98.4 %). The accuracy rates of TR-MRA for the detection of feeding arteries were 75.9 %, 91.7 %, and 80.0 % for SCAVSs, SDAVSs, and SEDAVSs respectively.
CONCLUSION: Time-resolved MR angiography showed excellent diagnostic performance for SAVSs screening. Additionally, this method can classify SAVSs and identify feeding arteries in SDAVSs with high diagnostic accuracy.
引用
- Cao, Feng, Yu, et al. High diagnostic performance of time-resolved MR angiography in spinal arteriovenous shunts. Eur J Radiol. 2023. PMID: 36868062. doi:10.1016/j.ejrad.2023.110755
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。