文献速递骨肌神经MR

多回波稳态采集与T2快速自旋回波序列相比可改善MRI图像质量及腰骶神经根病诊断效能

Multi-echo in steady-state acquisition improves MRI image quality and lumbosacral radiculopathy diagnosis efficacy compared with T2 fast spin-echo sequence.
PubMed 文献 · Neuroradiology · 2023-03-02

研究纳入72名受试者在3.0-T MRI上比较4分钟多回波稳态采集(MENSA)与6分钟可变翻转角快速自旋回波(CUBE)序列对腰骶丛神经根病变的评估。两名肌骨放射科医师独立评估图像质量和诊断能力,以手术报告为参考标准。MENSA图像质量评分及神经根SNR、髂静脉CNR、肌肉CNR均高于CUBE(P<0.05),MENSA诊断敏感度96.23%、特异度89.47%、准确率94.44%、AUC 0.929,CUBE分别为92.45%、84.21%、90.28%、0.883,两条相关ROC曲线无显著差异。

要点

  • MENSA图像质量评分3.679±0.47高于CUBE的3.038±0.68。
  • MENSA神经根SNR 36.935±8.33高于CUBE的27.777±7.41(P<0.05)。
  • MENSA诊断AUC 0.929,CUBE为0.883,两条ROC曲线无显著差异。

核心结论

  • 4分钟MENSA方案具有更优的图像质量和高的血管对比度,有潜力生成高分辨率腰骶神经根图像。

研究设计与样本

  • 在3.0-T MRI扫描仪上对72名受试者行MENSA(4分钟)和CUBE(6分钟)序列检查,两名肌骨放射科医师独立评估图像质量和诊断能力,以手术报告为参考标准。

关键影像表现/征象

  • MENSA图像质量评分3.679±0.47高于CUBE的3.038±0.68。
  • MENSA神经根SNR 36.935±8.33高于CUBE的27.777±7.41(P<0.05)。
  • MENSA髂静脉CNR 24.678±6.63高于CUBE的5.210±3.93(P<0.05)。
  • MENSA肌肉CNR 19.414±6.07高于CUBE的13.531±0.65(P<0.05)。

诊断标准与关键数值

  • 基于MENSA图像的诊断敏感度96.23%、特异度89.47%、准确率94.44%、AUC 0.929。
  • 基于CUBE图像的诊断敏感度92.45%、特异度84.21%、准确率90.28%、AUC 0.883。
  • 两条相关ROC曲线无显著差异。
  • 观察者内加权kappa 0.758,观察者间加权kappa 0.768-0.818,信度达充分至完美。

临床应用与阅片要点

  • MENSA序列可提供高于CUBE的图像质量及神经根、髂静脉和肌肉对比噪声比。
  • MENSA诊断腰骶神经根病变的敏感度、特异度、准确率和AUC数值均高于CUBE,但两条ROC曲线无显著差异。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: This study compares the performance of a 4-min multi-echo in steady-state acquisition (MENSA) with a 6-min fast spin echo with variable flip angle (CUBE) protocol for the assessment of lumbosacral plexus nerve root lesions.

METHODS: Seventy-two subjects underwent MENSA and CUBE sequences on a 3.0-T MRI scanner. Two musculoskeletal radiologists independently assessed the images for quality and diagnostic capability. A qualitative assessment scoring system for image quality and quantitative nerve signal-to-noise ratio (SNR) and iliac vein and muscle contrast-to-noise ratios (CNR) was applied. Using surgical reports as the reference, sensitivity, specificity, accuracy, and area under the receiver operating characteristic curves (AUC) were evaluated. Intraclass correlation coefficients (ICC) and weighted kappa were used to calculate reliability.

RESULTS: MENSA image quality rating (3.679 ± 0.47) was higher than for CUBE images (3.038 ± 0.68), and MENSA showed higher mean nerve root SNR (36.935 ± 8.33 vs. 27.777 ± 7.41), iliac vein CNR (24.678 ± 6.63 vs. 5.210 ± 3.93), and muscle CNR (19.414 ± 6.07 vs. 13.531 ± 0.65) than CUBE (P < 0.05). Weighted kappa and ICC values indicated good reliability. Sensitivity, specificity, and accuracy of diagnosis based on MENSA images were 96.23%, 89.47%, and 94.44%, respectively, and AUC was 0.929, compared with 92.45%, 84.21%, 90.28%, and 0.883 for CUBE images. The two correlated ROC curves were not significantly different. Weighted kappa values for intraobserver (0.758) and interobserver (0.768-0.818) reliability were substantial to perfect.

CONCLUSION: A time-efficient 4-min MENSA protocol exhibits superior image quality and high vascular contrast with the potential to produce high-resolution lumbosacral nerve root images.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Hu, Li, Hou, et al. Multi-echo in steady-state acquisition improves MRI image quality and lumbosacral radiculopathy diagnosis efficacy compared with T2 fast spin-echo sequence. Neuroradiology. 2023. PMID: 36862186. doi:10.1007/s00234-023-03130-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。